Appendix B Field Communicator Menu Tree - Fisher FIELDVUE DVC6200 Instruction Manual

Digital valve controller
Hide thumbs Also See for FIELDVUE DVC6200:
Table of Contents

Advertisement

Instruction Manual
D103605X012
Appendix B Field Communicator Menu Trees
This section contains the Field Communicator menu trees for instrument level HC, AD, PD, and ODV. It also contains
an alphabetized function/variable list to help locate the function/variable on the appropriate menu tree. All Fast Key
Sequences referenced in the menu trees assume the Online menu (see figure B-2) as the starting point.
Instrument Level HC, AD, PD, and ODV
Function/Variable
Actual Travel
Actuator Manufacturer
Actuator Model
Actuator Selection
Actuator Size
Actuator Style
Air
Alert Record Full Enable
Alert Record Not Empty Enable
Alert Switch Source
Analog Input
Analog Input (Calibration)
Analog Input Units
Area Units
Auto Calibration
Auxiliary Terminal Action
Auxiliary Terminal Action, Edit
Breakout Torque
Burst Mode
Calibration Button
Calibration Record
Calibration Time
Calibration Type
Calibrator
Change Control Mode
Change Instrument Mode
Change to HART 5
Change to HART 7
Change Write Protection
Clear Records
Control Mode
Critical NVM Failure Shutdown
Custom Characterization
Cycle Count Alert Enable
Cycle Count Alert Point
Cycle Counter
Cycle Count/Travel Accum Deadband
Days Powered Up
DD Information
Description
Device ID
Device Revision
Device Setup
Device Status
Drive Current Failure Shutdown
Drive Signal
See Figure
B-5
B-5
B-5
B-5
B-5
B-7
B-5
B-8
B-8
B-7
B-3, B-10
B-9
B-5
B-5
B-9
B-5
B-5
B-5
B-7
B-5
B-9
B-9
B-9
B-9
B-6, B-10
B-1, B-5
B-10
B-10
B-1, B-3, B-5
B-8, B-10
B-6, B-10
B-8
B-6, B-10
B-8
B-8
B-10
B-8
B-10
B-3
B-3, B-5
B-3
B-3
B-4
B-3, B-10
B-8
B-10
Field Communicator Menu Trees
Function/Variable
Drive Signal Alert Enable
Dynamic Torque
Edit Cycle Counts
Edit Instrument Time
Edit Travel Accumulator
Effective Area (Acutator)
End Point Pressure Control (EPPC)
EPPC Deviation (Alert Setup)
Fail Signal
Fallback Recovery
Feedback Connection
Firmware Revision
Flash Integrity Failure Shutdown
Flow Direction
Flow Tends to
Function
Hardware Revision (Device)
HART Long Tag
HART Tag
HART Universal Revision
Hi Limit/Cutoff Point
Hi Limit/Cutoff Select
HART Variable Assignments
Inlet Pressure
Input Characterization
Input Range Hi
Input Range Lo
Instrument Alert Record
Instrument Level
Instrument Mode
Instrument Serial Number
Instrument Time is Approximate Enable
Integral Enable
Integral Gain
Integrator Saturated High Enable
Integrator Saturated Lo Enable
Integrator Limit
Intgegral Dead Zone
Last AutoCal Status
Leak Class (Trim)
Length Units
Lever Arm Length
Lever Style
Limit Switch Trip Point
Limit Switch Valve Close
Limit Switch Valve Open
February 2017
See Figure
B-8
B-5
B-8
B-5, B-8
B-8
B-5
B-6
B-8
B-7
B-6, B-8, B-10
B-7
B-3
B-8
B-5
B-5
B-7
B-3
B-3, B-5
B-3, B-5
B-3
B-6, B-8
B-6, B-8
B-7
B-5
B-6, B-10
B-5
B-5
B-8
B-3
B-1, B-5
B-3, B-5
B-8
B-7
B-7
B-8
B-8
B-7
B-7
B-9
B-5
B-5
B-5
B-5
B-7
B-5
B-5
83