Siemens SCALANCE XB-200 Configuration Manual page 253

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XB-200:
Table of Contents

Advertisement

2. In the relevant row, enter the following data in the input boxes:
– Auth. Server Type
– RADIUS Server Address
– Server Port
– Shared Secret
– Shared Secret Confirmation
– Max. Retrans.: 3
– Primary server: No
3. Click the "Set Values" button.
4. If necessary, test the reachability of the RADIUS server.
Repeat this procedure for every server you want to enter.
Modifying servers
1. In the relevant row, enter the following data in the input boxes:
– Auth. Server Type
– RADIUS Server Address
– Server Port
– Shared Secret
– Shared Secret Confirmation
– Max. Retrans.
– Primary Server
2. Click the "Set Values" button.
3. If necessary, test the reachability of the RADIUS server.
Repeat this procedure for every server whose entry you want to modify.
Deleting servers
1. Click the check box in the first column before the row you want to delete to select the
entry for deletion.
Repeat this for all entries you want to delete.
2. Click the "Delete" button.
All selected entries are deleted and the display is refreshed.
SCALANCE XB-200/XC-200/XP-200 Web Based Management
Configuration Manual, 07/2016, C79000-G8976-C360-04
Configuring with Web Based Management
5.7 The "Security" menu