Configuring with Web Based Management
5.5 The "Layer 2" menu
● Entries
Enter the maximum number of samples to be stored at the same time.
Range of values: 1 - 65535
Factory setting: 24
● Interval [s]
Enter the interval after which the current status of the statistics will be saved as a sample.
Range of values: 1 - 3600
Factory setting: 3600
Steps in configuration
Enabling RMON statistics for individual ports
1. Select the check box "Setting" in the relevant row in table 2.
The "Entries" and "Interval[s]" boxes become active with the factory settings.
2. Enter the required values in the "Entries" and "Interval[s]" boxes.
3. Click the "Set Values" button.
Enabling RMON statistics for all ports
1. In the "Setting" drop-down list, select the "Enabled" entry in table 1.
2. Enter the required values in the "Entries" and "Interval[s]" boxes. If you do not change the
entries in both boxes, the factory defaults will be used for all ports.
3. Click the "Copy to Table" button.
The settings are adopted for all ports of table 2.
4. Click the "Set Values" button.
238
SCALANCE XB-200/XC-200/XP-200 Web Based Management
Configuration Manual, 07/2016, C79000-G8976-C360-04