Siemens SCALANCE XB-200 Configuration Manual page 158

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XB-200:
Table of Contents

Advertisement

Configuring with Web Based Management
5.4 The "System" menu
Description of the displayed boxes
The table has the following rows:
● Status
Shows the status of the PLUG. The following are possible:
– ACCEPTED
– NOT ACCEPTED
– NOT PRESENT
– FACTORY
● Device Group
Shows the SIMATIC NET product line that used the C-PLUG previously.
● Device type
Shows the device type within the product line that used the C-PLUG previously.
● Configuration Revision
The version of the configuration structure. This information relates to the configuration
options supported by the device and has nothing to do with the concrete hardware
configuration. This revision information does not therefore change if you add or remove
additional components (modules or extenders), it can, however, change if you update the
firmware.
● File System
Displays the type of file system on the PLUG.
● File System Size [bytes]
Shows the maximum storage capacity of the file system on the C-PLUG.
● File System Usage [bytes]
Displays the storage space in use in the file system of the C-PLUG.
● Info String
Shows additional information about the device that used the PLUG previously, for
example, order number, type designation, and the versions of the hardware and software.
The displayed software version corresponds to the version in which the configuration was
last changed. With the "NOT ACCEPTED" status, further information on the cause of the
problem is displayed.
● Modify PLUG
Select the setting from the drop-down list. You have the following options for changing
the configuration on the C-PLUG:
– Write Current Configuration to the PLUG
– Erase PLUG to factory default
158
There is a PLUG with a valid and suitable configuration in the device.
Invalid or incompatible configuration on the inserted PLUG.
No C-PLUG is inserted in the device.
PLUG is inserted and does not contain a configuration. This status is also displayed
when the PLUG was formatted during operation.
This option is available only if the status of the PLUG is "NOT ACCEPTED" or
"FACTORY".
The configuration in the internal flash memory of the device is copied to the PLUG.
Deletes all data from the C-PLUG and triggers low-level formatting.