Siemens SCALANCE XB-200 Configuration Manual page 102

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XB-200:
Table of Contents

Advertisement

Configuring with Web Based Management
5.4 The "System" menu
Description of the displayed boxes
The page contains the following boxes:
● Signaling Contact Method
Select the reaction of the signaling contact from the drop-down list. The following
reactions are possible:
– conventional
– User Defined
● Signaling Contact Status
To change the status of the signaling contact, select the "User defined" method from the
"Signaling Contact Method" drop-down list.
Select the status of the signaling contact from the drop-down list. The following statuses
are possible:
– Closed
– Open
With Table 1, you can enable or disable all check boxes of a column of Table 2 at once.
Table 1 has the following columns:
● All Events
Shows that the settings are valid for all events of table 2.
● E-mail / Trap / Log Table / Syslog / Faults
Enable or disable the required type of notification for all events. If "No Change" is
selected, the entries of the corresponding column in table 2 remain unchanged.
● Copy to table
If you click the button, the setting is adopted for all events of table 2.
102
Default setting for the signaling contact. An error/fault is displayed by the fault LED
and the signaling contact is opened. When the error/fault state no longer exists, the
fault LED goes off and the signaling contact is closed.
The way the signaling contact works does not depend on the error/fault that has
occurred. The signaling contact can be opened or closed as required by user actions.
Signaling contact is closed.
Signaling contact is opened.
SCALANCE XB-200/XC-200/XP-200 Web Based Management
Configuration Manual, 07/2016, C79000-G8976-C360-04