Siemens SCALANCE XB-000 Operating Instructions Manual

Siemens SCALANCE XB-000 Operating Instructions Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XB-000:

Advertisement

Quick Links

SIMATIC NET
Industrial Ethernet switches
SCALANCE XB-000
Operating Instructions
01/2022
A2B00077300-11
Introduction
Safety notices
Network topologies
Description of the device
Assembly and disassembly
Connecting up
Maintenance and
troubleshooting
Technical specifications
Dimension drawings
Approvals
1
2
3
4
5
6
7
8
9
10

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SCALANCE XB-000

  • Page 1 Introduction Safety notices Network topologies SIMATIC NET Description of the device Industrial Ethernet switches SCALANCE XB-000 Assembly and disassembly Connecting up Operating Instructions Maintenance and troubleshooting Technical specifications Dimension drawings Approvals 01/2022 A2B00077300-11...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    SCALANCE XB004-1LDG..................... 34 LEDs ..........................35 Assembly and disassembly ........................37 Safety notices for installation ..................... 37 Types of installation ......................40 Fixing onto standard mounting rails ................... 41 Wall mounting ........................42 Disassembly........................44 SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 4 SCALANCE XB008 ......................68 SCALANCE XB004-1G......................72 SCALANCE XB004-1LDG..................... 76 SCALANCE XB005G......................80 8.10 SCALANCE XB008G......................84 8.11 Mechanical stability (in operation) XB-000 ................. 88 Dimension drawings ..........................89 Approvals ............................. 91 Index ..............................99 SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 5: Introduction

    On the Operating Instructions Purpose of the Operating Instructions These Operating Instructions support you when commissioning networks with the Industrial Ethernet switches of the SCALANCE XB-000 product line. Validity of the Operating Instructions These operating instructions are valid for the following devices:...
  • Page 6 • On the Internet under the following address: 50305045 (https://support.industry.siemens.com/cs/ww/en/view/50305045) Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement –...
  • Page 7 (https://www.siemens.com/industrialsecurity) Catalogs You will find the article numbers for the Siemens products of relevance here in the following catalogs: • SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI • SIMATIC Products for Totally Integrated Automation and Micro Automation, catalog ST 70 •...
  • Page 8 • Place the modules only on conductive surfaces. • Pack, store and transport electronic modules and components only in conductive packaging such as metalized plastic or metal containers, conductive foam or household aluminum foil. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 9: Safety Notices

    This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non-hazardous locations only. This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations only. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 10 Safety notices SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 11: Network Topologies

    Which topologies can be implemented? Using the IE switches of the SCALANCE XB-000 product line, you can implement star topologies. Note Keep to the maximum permitted cable lengths of the devices you are using. You will find the permitted cable lengths in the section "Technical specifications (Page 57)".
  • Page 12 Network topologies Operator control and monitoring Laptop SCALANCE SCALANCE XB004-1 XB004-1 Field devices Industrial Ethernet (Twisted Pair) Industrial Ethernet (Fiber Optic) Figure 3-2 Example of an electrical/optical star topology with SCALANCE XB004-1 SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 13: Description Of The Device

    • SCALANCE XB004‑1G • SCALANCE XB004‑1LDG Note It is not possible to use IE switches of the SCALANCE XB-000 product line in a redundant ring because they do not support redundancy. Note If devices are supplied over long 24 V power supply lines or networks, measures are necessary to prevent interference by strong electromagnetic pulses on the supply lines.
  • Page 14: Product Overview

    XB004-1 XB004‑2 XB004- XB004- XB005 XB008 XB004- XB004- XB005G XB008G 1LDG TP (RJ-45) Fast Ethernet 10 / 100 Mbps Fiber multi‐ mode (SC) Fast Ethernet 100 Mbps Single-mode fi‐ ber (SC) Fast Ethernet 100 Mbps SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 15 1. Make sure that the package is complete. 2. Check all the parts for transport damage. Components of the product The following components are supplied with a SCALANCE XB-000: • IE switch SCALANCE XB-000 • 3-pin terminal block (power supply) •...
  • Page 16 FO trailing cable GP (50/125) 6XV1873-2D FO ground cable (50/125) 6XV1873-2G FO FRNC cable (50/125) 6XV1873-2B IE FC RJ-45 Plug 180 2x2 6GK1901‑1BB10‑2AA0 IE FC RJ-45 Plug 4x2 6GK1901‑1BB11‑2AA0 IE FC RJ-45 Plug 180 2x2 6GK1901‑1BB10‑2AB0 SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 17: Product Properties And Device Views

    Product properties and device views 4.3.1 SCALANCE XB004-1 Possible attachments The SCALANCE XB004-1 has four RJ-45 jacks and an SC socket for the connection of end devices or other network segments. Figure 4-1 SCALANCE XB004-1 SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 18: Scalance Xb004-2

    4.3 Product properties and device views 4.3.2 SCALANCE XB004-2 Possible attachments The SCALANCE XB004-2 has four RJ-45 jacks and two SC sockets for the connection of end devices or other network segments. Figure 4-2 SCALANCE XB004-2 SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 19: Scalance Xb004-1Ld

    4.3 Product properties and device views 4.3.3 SCALANCE XB004-1LD Possible attachments The SCALANCE XB004-1LD has four RJ-45 jacks and an SC socket for the connection of end devices or other network segments. Figure 4-3 SCALANCE XB004-1LD SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 20: Scalance Xb004-2Ld

    4.3 Product properties and device views 4.3.4 SCALANCE XB004-2LD Possible connections The SCALANCE XB004-2LD has four RJ-45 jacks and two SC sockets for the connection of end devices or other network segments. Figure 4-4 SCALANCE XB004-2LD SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 21: Scalance Xb005

    Description of the device 4.3 Product properties and device views 4.3.5 SCALANCE XB005 Possible connections The SCALANCE XB005 has five RJ-45 jacks for connection of end devices or other network segments. Figure 4-5 SCALANCE XB005 SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 22: Scalance Xb008

    Description of the device 4.3 Product properties and device views 4.3.6 SCALANCE XB008 Possible connections The SCALANCE XB008 has eight RJ-45 jacks for the connection of end devices or other network segments. Figure 4-6 SCALANCE XB008 SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 23: Scalance Xb004-1G

    4.3 Product properties and device views 4.3.7 SCALANCE XB004-1G Possible attachments The SCALANCE XB004-1G has four RJ-45 jacks capable of Gigabit and an SC socket for the connection of end devices or other network segments. Figure 4-7 SCALANCE XB004-1G SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 24: Scalance Xb004-1Ldg

    4.3 Product properties and device views 4.3.8 SCALANCE XB004-1LDG Possible attachments The SCALANCE XB004-1LDG has four RJ-45 jacks capable of Gigabit and an SC socket for the connection of end devices or other network segments. Figure 4-8 SCALANCE XB004-1LDG SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 25: Scalance Xb005G

    4.3 Product properties and device views 4.3.9 SCALANCE XB005G Possible attachments The SCALANCE XB005G has five RJ-45 jacks capable of Gigabit for connection of end devices or other network segments. Figure 4-9 SCALANCE XB005G SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 26: Scalance Xb008G

    Strain relief for the Ethernet cables In order to avoid mechanical stress on the Ethernet cables and resulting interruption of the contact, fasten the cables at a short distance from the connector using a cable guide or busbar. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 27: Pin Assignment

    Description of the device 4.4 TP ports (twisted pair) 4.4.1 Pin assignment With IE switches of the SCALANCE XB-000 product line, the twisted-pair ports are designed as RJ-45 jacks with MDI-X pin assignment (Medium Dependent Interface Autocrossover) of a network component. Pin number Assignment for SCALANCE XB‑000...
  • Page 28: Insulation Between The Tp Ports

    Devices not supporting autonegotiation must be set to 1000 Mbps/ half duplex, 100 Mbps/ half duplex or 10 Mbps half duplex. Note The IE switches of the SCALANCE XB-000 product line are plug-and-play devices that require no settings during commissioning. Auto polarity exchange If the pair of receiving cables is connected incorrectly (RD+ and RD- interchanged), the polarity is adapted automatically.
  • Page 29 Between ports of different port groups, an insulation voltage of 1.5 kV is adhered to (corresponds to IEEE802.3, Chapter 33.4.1.1, Environment B), e.g. between P1 and P2. The requirements for Environment A are met between ports of the same group, e.g. between P2 and P5. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 30: Fo Port (Fiber Optic)

    The transmission rate of the optical Fast Ethernet port is 100 Mbps. Transmission mode The transmission mode for 100Base-FX is specified in the IEEE 802.3 standard. Since the full duplex mode and the transmission rate cannot be modified for optical transmission, autonegotiation cannot be used. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 31: Scalance Xb004-2

    The maximum transmission range (segment length) with a signal attenuation of the fiber-optic cable of ≤ 1 dB/km at 1310 nm is: • with 62.5/125 µm fiber multimode SIMATIC NET cable: 4 km • with 50.0/125 µm fiber multimode SIMATIC NET cable: 5 km SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 32: Scalance Xb004-1Ld

    The maximum transmission range (segment length) is 26 km for a signal attenuation of the fiber- optic cable of ≤ 0.5 dB/km. Connectors The cables are connected to SC sockets. 4.5.4 SCALANCE XB004-2LD Transmission rate The transmission speed of the optical Fast Ethernet ports is 100 Mbps. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 33: Scalance Xb004-1G

    Multimode fiber-optic cable with a core diameter of 50 µm is used. Fiber-optic cables with a core diameter of 62.5 µm are not recommended for 1000Base-SX because this reduces the maximum segment length drastically. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 34: Scalance Xb004-1Ldg

    The light source is an "eye safe" class 1 laser with a wavelength of 1310 nm. Range The maximum transmission range (segment length) is 10 km for a signal attenuation of the fiber- optic cable of ≤ 0.5 dB/km. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 35: Leds

    LED color LED status Meaning Green Link exists, no data reception at port Green Flashing Link exists, data reception at port Green Flashing / flash on and Test phase during power on off in sequence SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 36 Description of the device 4.6 LEDs SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 37: Assembly And Disassembly

    Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Replacing components may impair suitability for Class 1, Division 2 or Zone 2. WARNING The device is intended for indoor use only. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 38 The equipment is intended to be installed within an enclosure/control cabinet. The inner service temperature of the enclosure/control cabinet corresponds to the ambient temperature of the module. Use cables with a maximum permitted operating temperature of at least 20 °C higher than the maximum ambient temperature. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 39 If the cable or housing socket exceeds 70 °C or the branching point of the cables exceeds 60 °C, special precautions must be taken. If the equipment is operated in an air ambient in excess of 40 °C, only use cables with admitted maximum operating temperature of at least 80 ℃. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 40: Types Of Installation

    Keep to the minimum clearances so that the convection ventilation of the device is not blocked. • Below at least 10 cm • Above at least 10 cm See also SIMATIC NET Industrial Ethernet TP and Fiber Optic Networks (http:// support.automation.siemens.com/WW/view/en/8763736) SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 41: Fixing Onto Standard Mounting Rails

    3. Fit the connectors for the power supply. See also section "Power supply (Page 49)" 4. Insert the terminal block into the sockets on the device. Figure 5-2 SCALANCE XB-000 mounted on the 35 mm DIN rail SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 42: Wall Mounting

    • 2 wall plugs, 6 mm in diameter and 30 mm long • 2 washers • 2 screws 3.5 mm in diameter and 35 mm long To mount the device on a wall, follow the steps below: SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 43 3. Fit the connectors for the power supply. See also section "Power supply (Page 49)". 4. Insert the terminal block into the socket on the device. 5. Screw the device to the wall. Figure 5-5 Wall mounting of the SCALANCE XB-000 SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 44: Disassembly

    For proper disassembly, observe the following: • Before starting work, ensure that the electricity is switched off. • Secure remaining connections so that no damage can occur as a result of disassembly if the system is accidentally started up. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 45: Connecting Up

    • Only remove the dust caps of optical transceivers and pre-configured cables shortly before connecting the cables. • Close unused optical sockets and plugs as well as pluggable transceivers and slots with the supplied protective caps. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 46 There is a risk of explosion due to equalizing currents between the hazardous area and the non- hazardous area. • Ground shielded cables that cross hazardous areas at one end only. • Lay a potential equalization conductor when grounding at both ends. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 47 Safety notices when using the device according to ATEX/IECEx and FM If you use the device under ATEX/IECEx or FM conditions, you must also observe the following safety notices in addition to the general safety notices for protection against explosion: SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 48: Wiring Rules

    ** See note "Wire end ferrules" Note Wire end ferrules Use crimp shapes with smooth surfaces, such as provided by square and trapeze shaped crimp cross sections. Crimp shapes with wave-shaped profile are unsuitable. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 49: Power Supply

    The power supply is connected via a plug-in terminal block with three terminals on the underside of the SCALANCE XB-000. The device is also connected to the functional grounding via this terminal block. You can find additional information in the section Grounding (Page 51). The power supply is non-floating.
  • Page 50: Power Supply 24 Vdc

    • XB004‑2 • XB004-1LD • XB004-2LD • XB005 • XB008 • XB004-1G • XB004-1LDG • XB005G • XB008G The following figure shows the position of the power supply and the assignment of the terminal block. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 51: Grounding

    This earth conducts fault currents to ground safely and according to DIN/VDE 0100 is a protective earth to protect people, animals and property from too high contact voltages. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 52: Twisted Pair Cable

    EMC interferences are discharged to ground. Functional grounding with SCALANCE XB-000 Grounding is not mandatory for operation of the SCALANCE XB-000 but it increases the resistance of the data transmission against interference. The functional ground must be implemented with low impedance.
  • Page 53 If there is not enough space to release the lock with your hand, you can also use a 2.5 mm screwdriver. You can then remove the IE FC RJ45 Plug 180 from the RJ-45 jack. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 54 Connecting up 6.6 IE FC RJ-45 Plug 180 SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 55: Maintenance And Troubleshooting

    Do not use solvents. Fuses The IE switches of the SCALANCE XB-000 product line have a resettable fuse / PTC. If the fuse triggers (all LEDs are off despite correctly applied power supply), the device should be disconnected from the power supply for approximately 30 minutes before turning it on again.
  • Page 56 If the power supply is too low, then the internal power supply will switch off causing the Power LED and all port LEDs to go off. The functionality of the SCALANCE XB-000 is no longer available. A power supply of at least 19.2 V is necessary for correct operation.
  • Page 57: Technical Specifications

    24 V DC Voltage range 19.2 to 28.8 V AC/DC Safety Extra Low Volt‐ age (SELV) Design 3-terminal plug-in block Current consumption Typically 24 V AC 230 mA Typically 24 V DC 105 mA SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 58 Forwarding frames CoS acc. to IEEE 802.1Q QoS priority queues 2 / 4 IEEE 802.1Q tags (VLAN ID, priority) transparent forwarding Maximum frame size 1536 bytes Forwarding of PRP frames (Parallel Re‐ dundancy Protocol) SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 59: Scalance Xb004-2

    4 Note The number of IE switches of the SCALANCE XB-000 product line connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XB‑000 product line, it is delayed by the store and forward function of the switch •...
  • Page 60 Mounting on a DIN rail • Wall mounting Switching properties Aging time 45 seconds Max. number of learnable MAC ad‐ 1024 dresses Response to LLDP frames Blocking Response to spanning tree BPDU Forwarding frames SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 61: Scalance Xb004-1Ld

    Forwarding of PRP frames (Parallel Re‐ dundancy Protocol) Note The number of IE switches of the SCALANCE XB-000 product line connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XB‑000 product line, it is delayed by the store and forward function of the switch •...
  • Page 62 EN 61000-6-2 Emission EN 61000-6-4 Degree of protection IP20 MTBF (EN/IEC 61709; 40 °C) 130 years Housing material Polycarbonate (plastic) Weight 165 g Dimensions (W x H x D) 45 x 100 x 87 mm SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 63 4 Note The number of IE switches of the SCALANCE XB-000 product line connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XB‑000 product line, it is delayed by the store and forward function of the switch •...
  • Page 64: Scalance Xb004-2Ld

    14 dB max. permitted FO cable attenuation with 2 dB link power margin Electrical data Power supply Rated voltage 24 V DC Voltage range 19.2 to 28.8 V DC Safe Extra Low Voltage (SELV) Design 3-terminal plug-in block SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 65 Forwarding frames CoS acc. to IEEE 802.1Q QoS priority queues 2 / 4 IEEE 802.1Q tags (VLAN ID, priority) transparent forwarding Maximum frame size 1536 bytes Forwarding of PRP frames (Parallel Re‐ dundancy Protocol) SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 66: Scalance Xb005

    4 Note The number of IE switches of the SCALANCE XB-000 product line connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XB‑000 product line, it is delayed by the store and forward function of the switch •...
  • Page 67 Forwarding frames CoS acc. to IEEE 802.1Q QoS priority queues 2 / 4 IEEE 802.1Q tags (VLAN ID, priority) transparent forwarding Maximum frame size 1536 bytes Forwarding of PRP frames (Parallel Re‐ dundancy Protocol) SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 68: Scalance Xb008

    5 Note The number of IE switches of the SCALANCE XB-000 product line connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XB‑000 product line, it is delayed by the store and forward function of the switch •...
  • Page 69 Max. number of learnable MAC ad‐ 1024 dresses Response to LLDP frames Blocking Response to spanning tree BPDU Forwarding frames CoS acc. to IEEE 802.1Q QoS priority queues IEEE 802.1Q tags (VLAN ID, priority) transparent forwarding SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 70 Forwarding of PRP frames (Parallel Re‐ dundancy Protocol) Note The number of IE switches of the SCALANCE XB-000 product line connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XB‑000 product line, it is delayed by the store and forward function of the switch •...
  • Page 71 Response to spanning tree BPDU Forwarding frames CoS acc. to IEEE 802.1Q QoS priority queues IEEE 802.1Q tags (VLAN ID, priority) transparent forwarding Maximum frame size 1536 bytes Forwarding of PRP frames (Parallel Re‐ dundancy Protocol) SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 72: Scalance Xb004-1G

    8.7 SCALANCE XB004-1G Note The number of IE switches of the SCALANCE XB-000 product line connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XB‑000 product line, it is delayed by the store and forward function of the switch •...
  • Page 73 Mounting on a DIN rail • Wall mounting Switching properties Aging time 300 seconds Max. number of learnable MAC ad‐ 8192 dresses Response to LLDP frames Blocking Response to spanning tree BPDU Forwarding frames SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 74 Forwarding of PRP frames (Parallel Re‐ dundancy Protocol) Note The number of IE switches of the SCALANCE XB-000 product line connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XB‑000 product line, it is delayed by the store and forward function of the switch •...
  • Page 75 Mounting on a DIN rail • Wall mounting Switching properties Aging time 45 seconds Max. number of learnable MAC ad‐ 16000 dresses Response to LLDP frames Blocking Response to spanning tree BPDU Forwarding frames SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 76: Scalance Xb004-1Ldg

    Forwarding of PRP frames (Parallel Re‐ dundancy Protocol) Note The number of IE switches of the SCALANCE XB-000 product line connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XB‑000 product line, it is delayed by the store and forward function of the switch •...
  • Page 77 < 4,000 m above sea level at max. +50 °C ambient temperature Design, dimensions and weight Immunity EN 61000-6-2 Emission EN 61000-6-4 Degree of protection IP20 MTBF (EN/IEC 61709; 40 °C) 146 years Housing material Polycarbonate (plastic) SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 78 Forwarding of PRP frames (Parallel Re‐ dundancy Protocol) Note The number of IE switches of the SCALANCE XB-000 product line connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XB‑000 product line, it is delayed by the store and forward function of the switch •...
  • Page 79 < 3,000 m above sea level at max. +55 °C ambient temperature < 4,000 m above sea level at max. +50 °C ambient temperature Design, dimensions and weight Immunity EN 61000-6-2 Emission EN 61000-6-4 Degree of protection IP20 SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 80: Scalance Xb005G

    Forwarding of PRP frames (Parallel Re‐ dundancy Protocol) Note The number of IE switches of the SCALANCE XB-000 product line connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XB‑000 product line, it is delayed by the store and forward function of the switch •...
  • Page 81 < 4,000 m above sea level at max. +50 °C ambient temperature Design, dimensions and weight Immunity EN 61000-6-2 Emission EN 61000-6-4 Degree of protection IP20 MTBF (EN/IEC 61709; 40 °C) 168 years SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 82 Forwarding of PRP frames (Parallel Re‐ dundancy Protocol) Note The number of IE switches of the SCALANCE XB-000 product line connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XB‑000 product line, it is delayed by the store and forward function of the switch •...
  • Page 83 45 x 100 x 87 mm Installation options • Mounting on a DIN rail • Wall mounting Switching properties Aging time 45 seconds Max. number of learnable MAC ad‐ 16000 dresses Response to LLDP frames Blocking SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 84: Scalance Xb008G

    Forwarding of PRP frames (Parallel Re‐ dundancy Protocol) Note The number of IE switches of the SCALANCE XB-000 product line connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XB‑000 product line, it is delayed by the store and forward function of the switch •...
  • Page 85 45 x 100 x 87 mm Installation options • Mounting on a DIN rail • Wall mounting Switching properties Aging time 300 seconds Max. number of learnable MAC ad‐ 8192 dresses Response to LLDP frames Blocking SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 86 Forwarding of PRP frames (Parallel Re‐ dundancy Protocol) Note The number of IE switches of the SCALANCE XB-000 product line connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XB‑000 product line, it is delayed by the store and forward function of the switch •...
  • Page 87 Response to spanning tree BPDU Forwarding frames CoS acc. to IEEE 802.1Q QoS priority queues IEEE 802.1Q tags (VLAN ID, priority) transparent forwarding Maximum frame size 1536 bytes Forwarding of PRP frames (Parallel Re‐ dundancy Protocol) SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 88: Mechanical Stability (In Operation) Xb-000

    8.11 Mechanical stability (in operation) XB-000 Note The number of IE switches of the SCALANCE XB-000 product line connected in a line influences the frame delay. When a frame passes through IE switches of the SCALANCE XB‑000 product line, it is delayed by the store and forward function of the switch •...
  • Page 89: Dimension Drawings

    Dimension drawings Figure 9-1 Dimension drawing, front view (example: SCALANCE XB004-1) SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 90 Dimension drawing, side view (example: SCALANCE XB004-1) Note The minimum bending radius of the optical and electrical signal cables used must not be fallen below. Example: SIMATIC NET FO standard cable - bending radius ≥ 70 mm SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 91: Approvals

    Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15273/cert). Notes for the manufacturers of machines The devices are not machines in the sense of the EC Machinery Directive.
  • Page 92 Siemens plc, Manchester M20 2UR You can find the current UK Declaration of Conformity for these products on the Internet pages under Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/ 15273/cert). The SIMATIC NET products described in this document meet the requirements of the following directives: •...
  • Page 93 "SIMATIC NET Product Information Use of subassemblies/modules in a Zone 2 Hazardous Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages under Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/view/78381013).
  • Page 94 • FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 95 • EN 61000-6-4 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments You will find the current versions of the standards in the currently valid RCM SDoCs (Self- Declaration of Conformity). SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 96 CLASS 1 LASER PRODUCT 1040.10 and 1040.11 Figure 10-1 FDA and IEC marking CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 97 The test was performed with a device and a connected communications partner that also meets the requirements of the standards listed above. When operating the device with a communications partner that does not comply with these standards, adherence to the corresponding values cannot be guaranteed. SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 98 Approvals SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 99: Index

    SCALANCE XB004-1G, 33 SCALANCE XB004-1LDG, 34 SCALANCE XB004-2, 31 SCALANCE XB004-2LD, 32 Permitted ambient conditions, 58, 60, 62, 65, 67, 69, SCALANCE XB004-1, 30 71, 73, 75, 77, 79, 81, 83, 85, 87 SCALANCE XB004-1LD, 32 SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 100 Optical connectors, 57 Optical parameters, 77, 79 Optical parameters, 57 Permitted ambient conditions, 77, 79 Permitted ambient conditions, 58 Permitted cable lengths, 77, 79 Permitted cable lengths, 57 Switching properties, 78, 80 Switching properties, 58 SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 101 SCALANCE XB004-1LDG, 76, 78 SCALANCE XB004-2, 59 SCALANCE XB004-2LD, 64 SCALANCE XB005G, 81, 82 SCALANCE XB008G, 84, 86 SCALANCE XB004-1, 57 SCALANCE XB004-1LD, 61 SCALANCE XB005, 66 SCALANCE XB008, 68, 70 Twisted pair cable, 52 SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...
  • Page 102 Index SCALANCE XB-000 Operating Instructions, 01/2022, A2B00077300-11...

Table of Contents