Description of the displayed boxes
To restart the device, the buttons on this page provide you with the following options:
● "Restart System" button
Click this button to restart the system. You must confirm the restart in a dialog box.
During a restart, the device is reinitialized, the internal firmware is reloaded, and the
device runs a self-test. The learned entries in the address table are deleted. You can
leave the browser window open while the device restarts. You then need to log in again.
● "Restore Factory Defaults and Restart" button
Click this button to restore the factory defaults for the configuration. The protected
defaults are also reset.
An automatic restart is triggered.
5.4.5
Load & Save
Overview of the file types
File type
Config
ConfigPack
Copyright
Debug
EDS
Firmware
GSDML
HTTPSCert
LogFile
MIB
RunningCLI
Script
StartupInfo
Users
SCALANCE XB-200 Web Based Management
Configuration Manual, 04/2015, C79000-G8976-C360-02
NOTICE
By resetting all the defaults to the factory settings, the IP address and the passwords
are also lost. Following this, the device can only be accessed via the serial interface,
using the Primary Setup Tool or using DHCP.
With the appropriate attachment, a previously correctly configured device can cause
circulating frames and therefore the failure of the data traffic.
Description
Start configuration
Detailed configuration information. for example, start configuration, users,
certificates
OSS licenses
This file contains information for Siemens Support.
Electronic Data Sheet (EDS)
Electronic data sheets for describing devices in the EtherNet/IP mode
Firmware
Information on the device properties
HTTPS certificate
File with entries from the event log table
Private MSPS MIB file "scalance_x_xb200_msps.mib"
This file contains an overview of the current configuration in the form of CLI
commands. You can download the text file. The file is not intended to be up-
loaded again unchanged.
CLI script file
Startup log file
File with user names and passwords
Configuring with Web Based Management