Configuring with Web Based Management
5.3 The "Information" menu
5.3.8.4

Packet Error

Bad received frames
This page shows how many bad frames were received per port. You cannot configure
anything on this page.
The displayed values are transferred by RMON.
On the page "Layer 2 > RMON > Statistics", you can set the ports for which values will be
displayed.
Description of the displayed values
The table has the following columns:
● Port
Shows the available ports. The port is made up of the module number and the port
number, for example port 0.1 is module 0, port 1.
● Error types
The other columns after the port number contain the absolute numbers of the incoming
frames according to their error type.
In the columns of the table, a distinction is made according to the following error types:
– 
 C RC
– 
 U ndersize
– Oversize
– 
 F ragments
64
Packets whose content does not match the CRC checksum.
Packets with a length less than 64 bytes.
Packets discarded because they were too long.
Packets with a length less than 64 bytes and a bad CRC checksum.
SCALANCE XB-200 Web Based Management