Siemens SCALANCE XB-200 Web Based Management page 128

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XB-200:
Table of Contents

Advertisement

Configuring with Web Based Management
5.5 The "Layer 2" menu
You can configure other settings in "Layer 2 > Spanning Tree".
● Standby
Enable or disable the standby redundancy function. You will find other settings in "Layer 2
> Ring Redundancy".
● Passive Listening
Enable or disable the passive listening function.
● RMON
If you select this check box, Remote Monitoring (RMON) allows diagnostics data to be
collected on the device, prepared and read out using SNMP by a network management
station that also supports RMON. This diagnostic data, for example port-related load
trends, allow problems in the network to be detected early and eliminated. Some of the
"Ethernet statistics counters" are part of the RMON function. If you disable RMON, the
"Ethernet statistics counter" in "Information > Ethernet Statistics" is no longer updated.
You can configure other settings in "Layer 2 > RMON".
● Dynamic Multicast
The following settings are possible:
– "-" (disabled)
– IGMP Snooping
You can configure other settings in "Layer 2 > Multicast".
● Mirroring
Enable or disable port mirroring. You can configure other settings in "Layer 2 > Mirroring".
● Loop Detection
Enable or disable the loop detection function. This allows loops in the network to be
detected. You will find other settings in "Layer 2 > Loop Detection"
128
Note
When using RSTP (Rapid Spanning Tree Protocol), loops involving duplication of
frames or frames being overtaken may occur briefly. If this is not acceptable in your
particular application, use the slower standard spanning tree mechanism.
Enables IGMP (Internet Group Management Protocol). You can configure other
settings in "Layer 2 > Multicast > IGMP".