Siemens SCALANCE XB-200 Web Based Management page 170

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XB-200:
Table of Contents

Advertisement

Configuring with Web Based Management
5.5 The "Layer 2" menu
Description of the displayed values
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports of table 2.
● Setting
Select the setting from the drop-down list. You have the following setting options:
– enabled
– disabled
– No Change
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
● Port
All available ports are listed in this column. Unavailable ports are not displayed.
● Setting
Enable or disable the blocking of multicast frames.
Steps in configuration
Enabling blocking for an individual port
1. Select the check box in the relevant row in table 2.
2. To apply the changes, click the "Set Values" button.
Enabling blocking for all ports
1. In the "Setting" drop-down list, select the "enabled" entry.
2. Click the "Copy to Table" button. The check box is enabled for all ports in table 2.
3. To apply the changes, click the "Set Values" button.
170
Blocking of multicast frames is enabled.
Blocking of multicast frames is disabled.
Table 2 remains unchanged.
SCALANCE XB-200 Web Based Management
Configuration Manual, 04/2015, C79000-G8976-C360-02