Siemens SCALANCE XB-200 Web Based Management page 50

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XB-200:
Table of Contents

Advertisement

Configuring with Web Based Management
5.3 The "Information" menu
Severity Filters
You can filter the entries in the table according to severity. Select the required entries in the
check boxes above the table.
● Info
Information
● Warning
Warnings
● Critical
Critical
To display all entries, select either all of them or leave the check boxes empty.
Description of the displayed values
The table has the following columns:
● Restart
Counts the number of restarts since you last reset to factory settings and shows the
device restart after which the corresponding event occurred.
● System Up Time
Shows the time the device has been running since the last restart when the described
event occurred.
If the system time is set, the time is also displayed at which the event occurred.
● System Time
Shows the date and time of the device.
● Severity
Sorts the entry into the categories above.
● Log Message
Displays a brief description of the event that has occurred.
Description of the buttons and input boxes
"Clear" button
Click this button to delete the content of the event log file. The display is also cleared. The
restart counter is only reset after you have restored the device to the factory settings and
restarted the device.
Note
The table can contain 400 entries for each severity. The number of entries in this table is
restricted to 1200. When this number is reached, the oldest entries are discarded. The table
remains permanently in memory.
"Show all" button
Click this button to display all the entries on the WBM page. Note that displaying all
messages can take some time.
50
SCALANCE XB-200 Web Based Management
Configuration Manual, 04/2015, C79000-G8976-C360-02