Description of the displayed values
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports of table 2.
● Setting
Select the setting from the drop-down list. If "No Change is selected, the entry in table 2
remains unchanged.
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
● Port
Shows the available ports. The port is made up of the module number and the port
number, for example port 0.1 is module 0, port 1.
● Setting
From the drop-down list, select whether the port should block or forward outgoing DCP
frames. You have the following options available:
– Forward
– Block
Steps in configuration
1. From the options in the drop-down list in the row, select which ports should support
sending DCP frames.
2. Click the "Set Values" button.
SCALANCE XB-200 Web Based Management
Configuration Manual, 04/2015, C79000-G8976-C360-02
DCP frames are forwarded via this port.
No outgoing DCP frames are forwarded via this port. It is nevertheless still possible to
receive via this port.
Configuring with Web Based Management
5.5 The "Layer 2" menu