Level Sensor - Genie TMZ-50/30 Service Manual

Hide thumbs Also See for TMZ-50/30:
Table of Contents

Advertisement

Section 4 • Repair Procedures
800-610-4101
ActionRental.com
GROUND CONTROLS
5 Starting at the upper corners of the touch pad,
remove all layers of the touch pad from the
control box lid.
The wire harness and large blue
connector will interfere if removing
the touch pad from the bottom.
6 Pull the large blue connector through the slot in
the control box lid and discard the old touch
pad. Remove any remaining sealant from the
slot.
7 Using a mild solvent, clean the surface of the
control box lid. Allow the surface to dry.
Component damage hazard. The
circuit board will become damaged
if it comes in contact with solvent.
Do not allow solvent to contact the
circuit board.
8 Remove all the brown backing material from the
new touch pad.
9 Insert the large blue connector from the new
touch pad through the slot. Carefully align the
battery power LED on the control box lid with
the window in the new touch pad and lightly lay
the touch pad onto the control box lid.
Repositioning the touch pad is
possible if the touch pad is lightly
adhered to the lid. Do not apply
any pressure to the touch pad.
10 When satisfied with the position of the touch
pad, firmly press down the entire surface of the
touch pad with your fingers.
11 Loosen the control box lid retaining fasteners
and open the lid.
12 Using RTV-type sealant, completely seal the
opening in the slot of the control box lid around
the wire harness.
13 Apply dielectric grease to the pins on the circuit
board at the connection marked
4 - 34
14 Install the large blue connector onto the circuit
board pins at the connection marked
Slide the connector parallel to the circuit board
until the connector is pushed onto the circuit
board pins no less than 0.2 inch / 5 mm.
15 Install the lid onto the control box and tighten
the retaining fasteners. Do not overtighten.
7-5

Level Sensor

One level sensor monitors the incline of the
turntable after the outriggers are deployed and the
machine is level. The Electronic Control Module
(ECM) is programmed to deactivate lift functions
and activate an alarm when a signal is received
from the level sensor, making the operator aware
of a potentially hazardous situation.
The tilt alarm sounds when the incline of the
chassis exceeds 1.5° in any direction. The tilt level
sensor is located below the ground control box.
How to Install and Calibrate the
Tilt Level Sensor
1 Perform this procedure with the machine on a
firm, level surface that is free of obstructions.
.
KEYPAD
TMZ-50/30
June 2005
KEYPAD
Be sure all pins are in the
connector.
Tip-over hazard. Failure to install
or calibrate the level sensor as
instructed could result in the
machine tipping over causing
death or serious injury. Do not
install or calibrate the level sensor
other than specified in this
procedure.
Part No. 65162
REV B
.