B-1

Inspect the Batteries

Proper battery condition is essential to good
machine performance and operational safety.
Improper fluid levels or damaged cables and
connections can result in component damage and
hazardous conditions.
Electrocution hazard. Contact with
electrically charged circuits could
result in death or serious injury.
Remove all rings, watches and
other jewelry.
Bodily injury hazard. Batteries
contain acid. Avoid spilling or
contacting battery acid. Neutralize
battery acid spills with baking soda
and water.
Perform this procedure after fully
charging the batteries.
For a more accurate determination
of battery condition, fully charge
the batteries and allow the
batteries to rest 24 hours before
performing this procedure to allow
the battery cells to equalize.
1 Put on protective clothing and eye wear.
2 Be sure that the battery cable connections are
free of corrosion.
Part No. 65162
Section 3 • Scheduled Maintenance Procedures

Checklist B Procedures

3 Be sure that the battery retaining fasteners and
cable connections are tight.
4 Remove the battery vent caps from all batteries
and check the specific gravity of each battery
cell with a hydrometer.
Result: If any battery cell displays a specific
gravity of less than 1.026, the battery must be
replaced.
5 Check the battery acid level of each battery. If
needed, replenish with distilled water to the
bottom of the battery fill tube. Do not overfill.
6 Install the battery vent caps.
7 Check each battery pack and verify that the
batteries are wired correctly. Refer to the
Battery Connection Diagram decal on the
machine.
8 Inspect the battery charger plug and pigtail for
damage or excessive insulation wear. Replace
as required.