PLC Setup Settings

Pulse Output 0 Origin Proximity Input Signal Type

Programming
Settings
Console setting
address
Word
Bits
268
04 to 07 0 hex: NC
1 hex: NO

Pulse Output 0 Limit Input Signal Type

Programming
Settings
Console setting
address
Word
Bits
268
00 to 03 0 hex: NC
1 hex: NO

Pulse Output 0 Origin Search/Return Initial Speed

Programming
Settings
Console setting
address
Word
Bits
258
00 to 15 00000000 to
000186A0 hex
259
00 to 15
(See note.)

Pulse Output 0 Origin Search High Speed

Programming
Settings
Console setting
address
Word
Bits
260
00 to 15 00000001 to
000186A0 hex
261
00 to 15
(See note.)
Pulse Output 0 Origin Search Proximity Speed
Programming
Settings
Console setting
address
Word
Bits
262
00 to 15 00000001 to
000186A0 hex
263
00 to 15
(See note.)
60
Default
0 hex
Specifies whether the Origin Proxim-
ity Input Signal for pulse output 0 is
normally closed or normally open.
Default
0 hex
Specifies whether the limit input sig-
nal for pulse output 0 is normally
closed or normally open.
Default
Specifies the starting speed (0 to
00000000
hex
100,000 pps) for the pulse output 0
origin search and origin return opera-
tions.
Note When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Default
00000000
Specifies the high speed setting (1 to
hex
100,000 pps) for pulse output 0 origin
search operation.
Note When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Default
00000000
Specifies the proximity speed setting
hex
(1 to 100,000 pps) for pulse output 0
origin search operation.
Note When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Function
Area flags/
---
Function
Area flags/
---
Function
Area flags/
---
Function
Area flags/
---
Function
Area flags/
---
Section 4-2
Related
Time when
Auxiliary
setting is read
by CPU Unit
bits
When operation
starts
Related
Time when
Auxiliary
setting is read
by CPU Unit
bits
When operation
starts
Related
Time when
Auxiliary
setting is read
by CPU Unit
bits
When operation
starts
Related
Time when
Auxiliary
setting is read
by CPU Unit
bits
When operation
starts
Related
Time when
Auxiliary
setting is read
by CPU Unit
bits
When operation
starts

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1m-cpu23Cj1m-cpu22

Table of Contents