High-Speed Counter 1 Operation Settings; High-Speed Counter 0 Pulse Input Setting (Pulse Input Mode); High-Speed Counter 1 Enable/Disable; High-Speed Counter 1 Counting Mode - Omron CJ1M-CPU21 Operation Manual

Cj-series built-in i/o cpu units
Hide thumbs Also See for CJ1M-CPU21:
Table of Contents

Advertisement

PLC Setup Settings

High-speed Counter 0 Pulse Input Setting (Pulse Input Mode)

Programming
Settings
Console setting
address
Word
Bits
50
00 to 03 0 hex: Differential
phase inputs
1 hex: Pulse +
direction inputs
2 hex: Up/Down
inputs
3 hex: Increment
pulse input

High-speed Counter 1 Operation Settings

High-speed Counter 1 Enable/Disable

Programming
Settings
Console setting
address
Word
Bits
53
12 to 15 0 hex: Don't Use
Counter.
1 hex*:
Use Counter
(60 kHz).
2 hex*:
Use Counter
(100 kHz).

High-speed Counter 1 Counting Mode

Programming
Settings
Console setting
address
Word
Bits
53
08 to 11 0 hex:
Linear mode
1 hex:
Ring mode
54
Default
0 hex
Specifies the pulse-input method for
high-speed counter 0.
Note When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Default
0 hex
Specifies whether or not high-speed
counter 1 is being used.
Note When high-speed counter 1 is
Default
0 hex
Specifies the counting mode for high-
speed counter 1.
Function
Function
enabled (setting 1 or 2), the
input operation settings for
IN6 and IN7 are disabled. The
input operation setting for IN2
is also disabled if the reset
method is set to Phase-Z sig-
nal + software reset.
Function
Section 4-2
Related
Time when
Auxiliary
setting is read
Area flags/
by CPU Unit
bits
---
When power is
turned ON
Related
Time when
Auxiliary
setting is read
Area flags/
by CPU Unit
bits
---
When power is
turned ON
Related
Time when
Auxiliary
setting is read
Area flags/
by CPU Unit
bits
---
When operation
starts