Wiring Examples

Operating Mode 1 Connection Example

42

Origin Search Operation

The origin search operation is completed when the rising edge of the Origin
Proximity Input Signal is detected and then the rising edge of the Origin Input
Signal is detected.
ORG(889)
instruction execution
Origin Proximity
Input Signal
Origin Input
Signal
Pulse signal

Example PLC Setup Settings

Programming
Bits
Console
address
256
00 to 03
257
00 to 03
04 to 07
08 to 11
12 to 15
268
00 to 03
04 to 07
08 to 11
12 to 15
In operating mode 1, the Error Counter Reset Output is turned ON when the
origin location is determined by detection of the rising edge of the Origin Input
Signal.
In this example, a servo driver is used and the encoder's phase-Z output is
used as the Origin Input Signal terminal. The servo driver is an OMRON W-
series Servo Driver.
Setting
1 hex
Enable origin search function for pulse
output 0.
0 hex
Operating Mode 0
0 hex
Reverse mode 1
1 hex
Read Origin Input Signal after Origin
Proximity Input Signal goes from OFF
to ON.
0 hex
Search direction is CW.
0 hex
Limit Input Signal is a NC contact.
1 hex
Origin Proximity Input Signal is a NO
contact.
1 hex
Origin Input Signal is a NO contact.
0 hex
---
Section 3-3
Time
Function