[9] Jogging operation
Communi
Title
cation
Function
No.
0260
Jog run frequency


0261
Jog run stop pattern
0262
Operation panel jog run mode

Input from external contacts - UP response

0264
time
Input from external contacts - UP frequency
0265

step
Input from external contacts - DOWN
0266

response time
Input from external contacts - DOWN

0267
frequency step

0268
Initial UP/DOWN frequency
0269
Initial up/down frequency rewriting

[10] Jump frequency
Communi
Title
cation
Function
No.
0270
Jump frequency 1


0271
Jumping width 1

0272
Jump frequency 2
0273
Jumping width 2

0274
Jump frequency 3


0275
Jumping width 3
[11] Preset speed operation frequency (8~15) [1/2]
Communi
Title
cation
Function
No.
0287
Preset speed operation frequency 8


0288
Preset speed operation frequency 9

0289
Preset speed operation frequency 10
0290
Preset speed operation frequency 11

0291
Preset speed operation frequency 12


0292
Preset speed operation frequency 13
Adjustment range
~20.0Hz
0:Deceleration stop
1:Coast stop
2:DC braking stop
0:Disabled
1:Operation panel jog run mode enabled
0.0~10.0 sec.
0.0~ Hz
0.0~10.0 sec.
0.0~ Hz
~ Hz
0:Not changed
1:Setting of  changed when power is
turned off
Adjustment range
0.0~ Hz
0.0~30.0Hz
0.0~ Hz
0.0~30.0Hz
0.0~ Hz
0.0~30.0Hz
Adjustment range
~ Hz
~ Hz
~ Hz
~ Hz
~ Hz
~ Hz
Sensorless vector/PG feedback control (●:Effective, -:Ineffective)
Minimum
setting unit
Default
Write during
Vector
(Panel/Communi
setting
running
control
cation)
0.1/0.01
5.0
Enabled
●/●
1/1
0
Disabled
●/●
1/1
0
Enabled
●/●
0.1/0.1
0.1
Enabled
●/●
0.1/0.01
0.1
Enabled
●/●
0.1/0.1
0.1
Enabled
●/●
0.1/0.01
0.1
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
1/1
1
Enabled
●/●
Sensorless vector/PG feedback control (●:Effective, -:Ineffective)
Minimum
setting unit
Default
Write during
Vector
(Panel/Communi
setting
running
control
cation)
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
Sensorless vector/PG feedback control (●:Effective, -:Ineffective)
Minimum
Write during
setting unit
Default
Vector
running
(Panel/Communi
setting
control
cation)
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
0.1/0.01
0.0
Enabled
●/●
PM
V/f
Reference
control
6. 10
6. 10
6. 10
6. 11
6. 11
6. 11
6. 11
6. 11
6. 11
PM
V/f
Reference
control
6. 12
6. 12
6. 12
6. 12
6. 12
6. 12
PM
V/f
Reference
control
5. 12
5. 12
5. 12
5. 12
5. 12
5. 12

Advertisement

Table of Contents
loading

Table of Contents