[18] Motor constant
Communi
Title
cation
Function
No.

0400
Auto-tuning 1
0401
Slip frequency gain


0402
Auto-tuning 2

0405
Motor rated capacity (motor name plate)
0406
Motor rated current (motor name plate)

Motor rated rotational speed (motor name

0407
plate)

0410
Motor constant 1 (torque boost)
0411
Motor constant 2 (no load current)

0412
Motor constant 3 (leak inductance)


0413
Motor constant 4 (rated slip)

0415
Exciting strengthening coefficient
0416
Stall prevention factor

*1: Default values vary depending on the capacity.  See the table of K-42.
*2: If the speed of rotation is set at 10,000min
[19] Torque limit
Communi
Title
cation
Function
No.
0440
Power running torque limit selection

0441
Power running torque limit level

0442
Regenerative braking torque limit selection


0443
Regenerative braking torque limit 1 level

0454
Constant output zone torque limit selection
Adjustment range
0:No auto-tuning
1:Initialize motor constant (0 after execution)
2:Continue operation continued after auto-tuning
(0 after execution)
3:Auto-tuning by input terminal signal
4:Motor constant auto calculation (0 after
execution)
0~150%
0:Disabled
1:Self-cooled motor
2:Forced air-cooled motor
0.10~630.0kW
0.1~2000A
100~60000min-1 *2
0.0~30.0%
10~90%
0~200(×0.1%)
0.1~25.0%
100~130%
10~250
-1
or more, the error messages  and  (if the speed of rotation is set at 10,000min
Adjustment range
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:
0:0~249.9%, 250.0:Disabled
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:
0.0~249.9%, 250.0:Disabled
0:Constant output limit
1:Constant torque limit
Sensorless vector/PG feedback control (●:Effective, -:Ineffective)
Minimum
setting unit
Default
Write during
Vector
(Panel/Communi
setting
running
control
cation)
1/1
0
Disabled
●/●
1/1
70
Enabled
●/-
1/1
0
Disabled
●/●
0.01/0.01
*1
Disabled
●/●
0.1/0.1
*1
Disabled
●/●
1/1
*1
Disabled
●/●
0.1/0.1
*1
Enabled
●/●
1/1
*1
Disabled
●/●
1/1
*1
Disabled
●/●
0.1/0.1
*1
Disabled
●/●
1/1
100
Disabled
●/●
1/1
100
Disabled
●/●
-1
) are displayed alternately.
Sensorless vector/PG feedback control (●:Effective, -:Ineffective)
Minimum
setting unit
Default
Write during
Vector
(Panel/Communi
setting
running
control
cation)
1/1
4
Enabled
●/●
0.1/0.01
250.0
Enabled
●/●
1/1
4
Enabled
●/●
0.1/0.01
250.0
Enabled
●/●
1/1
0
Disabled
●/●
PM
V/f Constant Reference
control
-
-
6. 19
-
-
6. 19
-
-
6. 19
-
-
6. 19
-
-
6. 19
-
-
6. 19
-
-
6. 19
-
-
6. 19
-
-
6. 19
-
-
6. 19
-
-
6. 20
-
-
6. 20
PM
V/f Constant Reference
control
-
6. 21
-
6. 21
-
6. 21
-
6. 21
-
6. 21