Integrating Wattmeter - Toshiba TOSVERT VF-PS1 Instruction Manual

Variable torque inverter
Hide thumbs Also See for TOSVERT VF-PS1:
Table of Contents

Advertisement

 Trace data communication number
Communication
No.
E000
E100 
E199 
E200 
E299 
E300 
E399 
E400 
E499 
Ex.) When operation frequency data is acquired through a communication device
Data acquired (  ) h=8000  8000×0.01Hz=80.0Hz
 Relationship between pointer and data
The table below shows the relationship between pointer (E000 set value) and trace data (1 to 4).
Pointer (E000 set value)
Trace data 1 ( E100 ~ E199 )
Trace data 2 ( E200 ~ E299 )
Trace data 3 ( E300 ~ E399 )
Trace data 4 ( E400 ~ E499 )
<Example of setting> If E000 is set to  :
(Earliest data)
Trace data 1
E102
Trace data 2
E202
Trace data 3
E302
Trace data 4
E402
Note 1: Use the parameters  through  to specify the types of trace data (1 to 4).
Note 2: Communication numbers E000 is automatically incremented by the inverter when data is traced
continuously.
* In ordinary cases, these parameters do not need to be rewritten.
6.33

Integrating wattmeter

 : Integrating wattmeter retention selection
 : Integrating wattmeter display unit selection
 Function
At the main power off ,it is selectable whether retention of integral output power values or not.
And also, the display unit is selectable.
The integrating wattmeter display can be cleared by external input signal by assignment of the terminal
function. Input terminal function 74, 75 (Integrating wattmeter display clear)
Title

Integrating wattmeter retention selection

Integrating wattmeter display unit selection
Minimum setting
Function
/readout unit
Trace data 1~4 pointer
Data 1 of trace data 1
Data 2~99 of trace data 1
Data 100 of trace data 1
Data 1 of trace data 2
Data 2~99 of trace data 2
Data 100 of trace data 2
Data 1 of trace data 3
Data 2~99 of trace data 3
Data 100 of trace data 3
Data 1 of trace data 4
Data 2~99 of trace data 4
Data 100 of trace data 4

E100
E200
E300
E400
(Latest data)
~
E199, E100, E101
~
E299, E200, E201
~
E399, E300, E301
~
E499, E400, E401
Function
F-71
Setting/readout range
 / 
 ~ 
 / 
 ~ 
 / 
 ~ 
 / 
 ~ 
 / 
 ~ 
 / 
 ~ 
 / 
 ~ 
 / 
 ~ 
 / 
 ~ 
 / 
 ~ 
 / 
 ~ 
 / 
 ~ 
 / 
 ~ 


E101
E102
E201
E202
E301
E302
E401
E402
Adjustment range
 : Disabled
 : Enabled
 : 1 = 1 kWh
 : 1 = 10 kWh
 : 1 = 100 kWh
 : 1 = 1000 kWh
 : 1 = 10000 kWh
E6581386
Default setting















~
~
E198
E199
~
E298
E299
~
E398
E399
~
E498
E499
Default setting

Accoding to
model
 Refer to
page K-42.
6