[25] Meter output
Communi
Title
cation
Function
No.
0671
AM terminal meter adjustment
0672
MON1 terminal meter selection
0673
MON1 terminal meter adjustment
0674
MON2 terminal meter selection
0675
MON2 terminal meter adjustment
0676
Pulse output function selection
0677
Selection of number of pulses
0678
Constant at the time of filtering
0681
FM voltage/current output switching
0682
FM output gradient characteristic
0683
FM bias adjustment
0684
FM output filter
0685
AM output gradient characteristic
0686
AM bias adjustment
0688
MON1 voltage/current output switching
0689
MON1 output gradient characteristic
0690
MON1 bias adjustment
0691
MON2 voltage/current output switching
0692
MON2 output gradient characteristic
0693
MON2 bias adjustment
This parameter moves to a fundamental parameter.
*1: For the adjustment range, see the table on page K-35.
*2: For details, refer to Instruction Manual (E6581341) specified in Section 6.36.
Adjustment range
-
0~76 *1
-
0~76 *1
-
0~49 *1
1.00~43.20kHz
4msec, 8msec~100msec
0:Voltage 0~10V output
1:Current 0~20mA output
0:Negative gradient (descending)
1:Positive gradient (ascending)
-10.0~100.0%
0:No filter
1:Filter approx. 10ms
2:Filter approx. 15ms
3:Filter approx. 30ms
4:Filter approx. 60ms
5:Filter approx. 120ms
6:Filter approx. 250ms
7:Filter approx. 500ms
8:Filter approx. 1s
0:Negative inclination (downward slope)
1:Positive inclination (upward slope)
-10.0~100.0%
0:Voltage -10~10V output
1:Voltage 0~10V output
2:Current 0~20mA output
0:Negative inclination (downward slope)
1:Positive inclination (upward slope)
-10.0~100.0%
0:Voltage -10~10V output
1:Voltage 0~10V output
2:Current 0~20mA output
0:Negative inclination (downward slope)
1:Positive inclination (upward slope)
-10.0~100.0%
Sensorless vector/PG feedback control (●:Effective, -:Ineffective)
Minimum
setting unit
Default
Write during
Vector
(Panel/Communi
setting
running
control
cation)
1/1
-
Enabled
●/●
1/1
4
Enabled
●/●
1/1
-
Enabled
●/●
1/1
5
Enabled
●/●
1/1
-
Enabled
●/●
1/1
0
Enabled
●/●
0.01/0.01
3.84
Enabled
●/●
1/1
64
Enabled
●/●
1/1
0
Disabled
●/●
1/1
1
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
1
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
1/1
1
Disabled
●/●
1/1
1
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
1/1
1
Disabled
●/●
1/1
1
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
PM
V/f Constant Reference
control
●
●
5. 16
●
●
*2
●
●
*2
●
●
*2
●
●
*2
●
●
6. 30. 1
●
●
6. 30. 1
●
●
5. 16
●
●
6. 30. 3
●
●
6. 30. 3
●
●
6. 30. 3
●
●
5. 16
●
●
6. 30. 3
●
●
6. 30. 3
●
●
*2
●
●
*2
●
●
*2
●
●
*2
●
●
*2
●
●
*2