Toshiba TOSVERT VF-PS1 Instruction Manual page 271

Variable torque inverter
Hide thumbs Also See for TOSVERT VF-PS1:
Table of Contents

Advertisement

[25] Meter output
Communi
Title
cation
Function
No.

0671
AM terminal meter adjustment

0672
MON1 terminal meter selection
0673
MON1 terminal meter adjustment

0674
MON2 terminal meter selection


0675
MON2 terminal meter adjustment

0676
Pulse output function selection
0677
Selection of number of pulses


0678
Constant at the time of filtering
0681
FM voltage/current output switching


0682
FM output gradient characteristic

0683
FM bias adjustment
0684
FM output filter


0685
AM output gradient characteristic
0686
AM bias adjustment


0688
MON1 voltage/current output switching

0689
MON1 output gradient characteristic

0690
MON1 bias adjustment

0691
MON2 voltage/current output switching

0692
MON2 output gradient characteristic

0693
MON2 bias adjustment
This parameter moves to a fundamental parameter.
*1:  For the adjustment range, see the table on page K-35.
*2:  For details, refer to Instruction Manual (E6581341) specified in Section 6.36.
Adjustment range
-
0~76 *1
-
0~76 *1
-
0~49 *1
1.00~43.20kHz
4msec, 8msec~100msec
0:Voltage 0~10V output
1:Current 0~20mA output
0:Negative gradient (descending)
1:Positive gradient (ascending)
-10.0~100.0%
0:No filter
1:Filter approx. 10ms
2:Filter approx. 15ms
3:Filter approx. 30ms
4:Filter approx. 60ms
5:Filter approx. 120ms
6:Filter approx. 250ms
7:Filter approx. 500ms
8:Filter approx. 1s
0:Negative inclination (downward slope)
1:Positive inclination (upward slope)
-10.0~100.0%
0:Voltage -10~10V output
1:Voltage 0~10V output
2:Current 0~20mA output
0:Negative inclination (downward slope)
1:Positive inclination (upward slope)
-10.0~100.0%
0:Voltage -10~10V output
1:Voltage 0~10V output
2:Current 0~20mA output
0:Negative inclination (downward slope)
1:Positive inclination (upward slope)
-10.0~100.0%
Sensorless vector/PG feedback control (●:Effective, -:Ineffective)
Minimum
setting unit
Default
Write during
Vector
(Panel/Communi
setting
running
control
cation)
1/1
-
Enabled
●/●
1/1
4
Enabled
●/●
1/1
-
Enabled
●/●
1/1
5
Enabled
●/●
1/1
-
Enabled
●/●
1/1
0
Enabled
●/●
0.01/0.01
3.84
Enabled
●/●
1/1
64
Enabled
●/●
1/1
0
Disabled
●/●
1/1
1
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
1
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
1/1
1
Disabled
●/●
1/1
1
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
1/1
1
Disabled
●/●
1/1
1
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
PM
V/f Constant Reference
control
5. 16
*2
*2
*2
*2
6. 30. 1
6. 30. 1
5. 16
6. 30. 3
6. 30. 3
6. 30. 3
5. 16
6. 30. 3
6. 30. 3
*2
*2
*2
*2
*2
*2