Daikin R71FUV1 Service Manual page 401

Skyair series service diagnosis
Table of Contents

Advertisement

Si20-701_B
Does the
fuse (∗2) have
continuity?
CHECK 13
fan output voltage.
Is the
output voltage
normal?
After turning OFF the
power supply, correctly
insert the connector of
the fan motor and then
restore the power.
Note:
∗1 Optional accessories refer to wire adaptor, auto grill
and other accessories.
∗2 RZQ71B9V3B⇒No fuse
RZQS71·100B7V3B⇒No fuse
RZQ100~140C7V1B⇒F6U
RZQ125·140C7V1B⇒F6U
RZQ100~140B8W1B⇒F1U
CHECK 13
394
C
NO
YES
Check the
NO
YES
YES
D
Refer to P.482.
Troubleshooting by Remote Controller
Replace the fuse.
RZQ71B9,
RZQS71·100B
7 (1φ),
RZQ100~140B
8 (3φ):
Replace the
inverter PCB
(A2P).
RZQ100~140C7,
RZQS125·140
C7 (1φ):
Replace the
outdoor unit
PCB (A2P).