Dbosync; Clear The Dbosync Alarm; Disconnected; Clear The Disconnected Alarm - Cisco ONS 15600 SDH Troubleshooting Manual

Hide thumbs Also See for Cisco ONS 15600 SDH:
Table of Contents

Advertisement

Chapter 2 Alarm Troubleshooting

2.6.35 DBOSYNC

The Standby Database Out of Synchronization alarm occurs when the standby TSC card "To be Active"
database does not synchronize with the active database on the active TSC card.
If you reset the active TSC card while this alarm is raised, you lose current provisioning.
Caution

Clear the DBOSYNC Alarm

Save a backup copy of the active TSC card database. Refer to the "Maintain the Node" chapter in the
Step 1
Cisco ONS 15600 SDH Procedure Guide for instructions.
Make a minor provisioning change to the active database to see if applying a provisioning change clears
Step 2
the alarm by completing the following steps:
a.
b.
Step 3
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1 800 553-2447).

2.6.36 DISCONNECTED

The Disconnected is raised when CTC has been disconnected from the node. The alarm is cleared when
CTC is reconnected to the node.

Clear the DISCONNECTED Alarm

Restart the CTC application.
Step 1
Step 2
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
for more information or call Cisco TAC (1-800-553-2447).
July 2010
Default Severity: Major (MJ), Service-Affecting (SA)
Logical Object: NE
In node view, click the Provisioning > General > General tabs.
In the Description field, make a small change such as adding a period to the existing entry.
The change causes a database write but does not affect the node state. The write could take up to a
minute.
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: SYSTEM
Cisco ONS 15600 SDH Troubleshooting Guide, R8.0
2.6.35 DBOSYNC
2-39

Advertisement

Table of Contents
loading