2.4 Alarm List by Logical Object Type
Table 2-8
ONS 15600 SDH Alarm List by Logical Object in Alarm Profile (continued)
EQPT: MFGMEM (CR)
EQPT: OPEN-SLOT (MN)
EQPT: PWR-FAIL-A (MN)
EQPT: PWR-FAIL-B (MN)
EQPT: PWR-FAIL-RET-A (MN)
EQPT: PWR-FAIL-RET-B (MN)
EQPT: PWRRESTART (NA)
EQPT: SFTWDOWN (MN)
EQPT: SW-VER (NA)
EXT-SREF: FRCDSWTOPRI (NA)
EXT-SREF: FRCDSWTOSEC (NA)
EXT-SREF: FRCDSWTOTHIRD (NA) PWR: EHIBATVG (MJ)
EXT-SREF: MANSWTOPRI (NA)
EXT-SREF: MANSWTOSEC (NA)
EXT-SREF: MANSWTOTHIRD (NA) PWR: LWBATVG (MJ)
EXT-SREF: SWTOPRI (NA)
EXT-SREF: SWTOSEC (NA)
EXT-SREF: SWTOTHIRD (NA)
EXT-SREF: SYNCPRI (MN)
EXT-SREF: SYNCSEC (MN)
EXT-SREF: SYNCTHIRD (MN)
FAN: FAN-DEGRADE (MN)
FAN: FAN-FAIL (CR)
FAN: FAN-FAIL-PARTIAL (MJ)
FAN: FAN-PWR (MN)
FAN: IMPROPRMVL (CR)
FAN: MFGMEM (CR)
GIGE: CARLOSS (MJ)
GIGE: LPBKFACILITY (NA)
GIGE: LPBKTERMINAL (NA)
NE-SREF: FRCDSWTOINT (NA)
NE-SREF: FRCDSWTOPRI (NA)
NE-SREF: FRCDSWTOSEC (NA)
Cisco ONS 15600 SDH Troubleshooting Guide, R8.0
2-10
PPM: IMPROPRMVL (CR)
PPM: LASER-BIAS (CR)
PPM: LASER-OVER-TEMP (CR)
PPM: LO-LASERBIAS (MN)
PPM: LO-TXPOWER (MN)
PPM: MANRESET (NA)
PPM: MEA (CR)
PPM: MFGMEM (CR)
PPM: NON-CISCO-PPM (MN)
PPM: PROV-MISMATCH (MN)
PPM: UNQUAL-PPM (MN)
PWR: ELWBATVG (MJ)
PWR: HIBATVG (MJ)
PWR: PWR (MJ)
PWR: VOLT-MISM (NA)
STMN: ALS (NA)
STMN: APSB (MN)
STMN: APSC-IMP (MN)
STMN: APSCDFLTK (MN)
STMN: APSCINCON (MN)
STMN: APSCM (MJ)
STMN: APSCNMIS (MJ)
STMN: CHANLOSS (NA)
STMN: E-W-MISMATCH (MJ)
STMN: EXERCISE-RING-FAIL (NA)
STMN: EXTRA-TRAF-PREEMPT
(MJ)
STMN: FAILTOSW (NA)
STMN: FAILTOSWR (NA)
STMN: FAILTOSWS (NA)
STMN: FE-FRCDWKSWBK-SPAN
(NA)
STMN: FE-FRCDWKSWPR-RING
(NA)
Chapter 2 Alarm Troubleshooting
STMN: SSM-PRC (NA)
STMN: SSM-SDH-TN (NA)
STMN: SSM-SETS (NA)
STMN: SSM-SMC (NA)
STMN: SSM-STU (NA)
STMN: SYNC-FREQ (NA)
STMN: WKSWPR (NA)
STMN: WTR (NA)
STMN: WVL-OUT-OF-LOCK (MJ)
VCMON-HP: AU-AIS (NR)
VCMON-HP: AU-LOP (CR)
VCMON-HP: AUTOSW-AIS-SNCP (NR)
VCMON-HP: AUTOSW-LOP-SNCP (NA)
VCMON-HP: AUTOSW-SDBER-SNCP
(NA)
VCMON-HP: AUTOSW-SFBER-SNCP
(NA)
VCMON-HP: AUTOSW-UNEQ-SNCP
(NA)
VCMON-HP: FAILTOSW-HO (NA)
VCMON-HP: FORCED-REQ (NA)
VCMON-HP: HP-DEG (NA)
VCMON-HP: HP-EXC (NA)
VCMON-HP: HP-PLM (CR)
VCMON-HP: HP-RFI (NR)
VCMON-HP: HP-TIM (MN)
VCMON-HP: HP-UNEQ (CR)
VCMON-HP: LOCKOUT-REQ (NA)
VCMON-HP: LPBKCRS (NA)
VCMON-HP: MAN-REQ (NA)
VCMON-HP: ROLL (NA)
VCMON-HP: ROLL-PEND (NA)
VCMON-HP: WKSWPR (NA)
VCMON-HP: WTR (NA)
July 2010