Table 4-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
EID-2127
You cannot add this span. It would cause the following
circuit(s) to occupy different {0} regions on different spans:
{1}
Either select a different span or delete the above circuit(s).
EID-2128
The state is invalid.
EID-2129
You cannot use same slot for east and west protect ports.
EID-2130
The ring ID value, {0}, is not valid. Please enter a valid number
between 0 and 9999.
EID-2131
The reversion cannot be set to INCONSISTENT.
EID-2135
The overhead circuit preferences could not be stored:
{0}
EID-2137
An error occurred during the circuit merge.
{0}
EID-2138
Not all destinations could be deleted.
Please try again.
EID-2139
An error occurred while updating the destinations.
EID-2143
No online help version was selected.
The online help book cannot be deleted.
EID-2144
An error occurred while deleting the online help book(s).
{0}
EID-2145
No nodes appear to have a Cisco IOS card.
EID-2146
This is a security violation.
You may only logout of your own account.
EID-2147
This is a security violation.
You may only change your own account.
EID-2148
This is a security violation.
You cannot delete the account under which you are currently
logged in.
WID-2149
There is no exportable content in this view.
WID-2150
The node {0} is not initialized.
Please wait and try again.
WID-2152
Spanning tree protection is being disabled for this circuit.
WID-2153
Adding this drop will make the circuit a PCA circuit.
WID-2154
Monitor circuits cannot be created on a port grouping circuit.
WID-2155
Switch counts might not be fully supported on some nodes.
{0}
Cisco ONS 15600 SDH Troubleshooting Guide, R8.0
4-10
Chapter 4 Error Messages
Description
A circuit cannot occupy different STS
regions on different spans. You may add a
different span or delete the specified circuit.
An internal error occurred while trying to
remove a span from a MS-SPRing. This
alarm occurs in the network-level
MS-SPRing creation dialog box.
Refer to the error message text.
Enter a ring ID value between 0 and 9999.
You must select another reversion type.
Input/Output error. Unable to store
overhead circuit preferences.
There was an error while merging the
circuits.
Refer to the error message text.
There was an error in updating the circuit
destinations.
Select the version of online help, and
proceed.
You cannot delete the specified online help.
Refer to error message.
You cannot logout of an account other than
your own.
You cannot change an account other than
your own.
You cannot delete the account you are
currently loggd in.
Refer to the error message text.
Wait till the specified node is initialized and
try again.
Refer to the warning message text.
Refer to the warning message text.
Refer to the warning message text.
The specified nodes do not support switch
counts completely.
July 2010