Chapter 2 Alarm Troubleshooting
Whenever TSC cards are changed from active to standby, it takes approximately 12 minutes to
Note
completely synchronize to the timing source because the Stratum 3E timing module is being adopted.

2.6.196 VOLT-MISM

The Power Monitoring Mismatch Between Control Cards alarm is raised against the shelf when the
power voltages of both TSC cards are out of range of each other by more than 5Vdc.

Clear the VOLT-MISM Condition

Check the incoming voltage level to the shelf using a voltmeter. Follow site practices or consult the
Step 1
"Install the Shelf and FMECs" chapter in the Cisco ONS 15600 SDH Procedure Guide for power
installation procedures.
Correct any incoming voltage issues.
Step 2
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 3
for more information or call Cisco TAC (1 800 553-2447).

2.6.197 WKSWPR

The Working Switched To Protection condition occurs when a line has a failure, the
alarm on page 2-86
This condition is also raised when you use the FORCE RING, FORCE SPAN, or MANUAL SPAN
command at the network level. WKSWPR is visible on the network view Alarms, Conditions, and
History tabs.

Clear the WKSWPR Condition

Complete the
Step 1
Step 2
If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).

2.6.198 WTR

July 2010
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Object: PWR
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Objects: VCMON-HP
or the
"MS-DEG" condition on page
"Clear the LOF (STMN) Alarm" procedure on page
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
2-98.
2-83. (It is also used for LOS.)
Cisco ONS 15600 SDH Troubleshooting Guide, R8.0
2.6.196 VOLT-MISM
"LOS (STMN)"
2-119