Configure Up-MEPs on ingress ports, ports that send traffic towards the bridge relay. Configure Down-MEPs
on egress ports, ports that send traffic away from the bridge relay.
Figure 5. Maintenance End Points

Implementation Information

The S-Series has a single MAC address for all physical/LAG interfaces and hence only one MEP is allowed per
MA (per VLAN or per MD level).

Configuring the CFM

To configure the CFM, follow these steps:
1
Configure the ecfmacl CAM region using the cam-acl command.
2
Enable Ethernet
CFM.
3
Create a Maintenance
4
Create a Maintenance
5
Create Maintenance
6
Use CFM tools:
a
Continuity Check
b
Loopback Message and
c
Linktrace Message and
Domain.
Association.
Points.
Messages.
Response.
Response.
802.1ag