Continuity Check Messages - Dell S4048T Configuration Manual

On system
Table of Contents

Advertisement

To display the MEP and MIP databases, use the following commands.
Display the MEP Database.
EXEC Privilege mode
show ethernet cfm maintenance-points remote detail [active | domain {level |
name} | expired | waiting]
Display the MIP Database.
EXEC Privilege mode
show ethernet cfm mipdb
Example of Displaying the MEP Database
Dell#show ethernet cfm maintenance-points remote detail
MAC Address: 00:01:e8:58:68:78
Domain Name: cfm0
MA Name: test0
Level: 7
VLAN: 10
MP ID: 900
Sender Chassis ID: Force10
MEP Interface status: Up
MEP Port status: Forwarding
Receive RDI: FALSE
MP Status: Active
Setting the MP Database Persistence
To set the database persistence, use the following command.
Set the amount of time that data from a missing MEP is kept in the continuity check database.
ECFM DOMAIN
database hold-time minutes
The default is 100 minutes.
The range is from 100 to 65535 minutes.

Continuity Check Messages

Continuity check messages (CCM) are periodic hellos.
Continuity check messages:
discover MEPs and MIPs within a maintenance domain
detect loss of connectivity between MEPs
detect misconfiguration, such as VLAN ID mismatch between MEPs
detect unauthorized MEPs in a maintenance domain
CCMs are multicast Ethernet frames sent at regular intervals from each MEP. They have a destination address
based on the MD level (01:80:C2:00:00:3X where X is the MD level of the transmitting MEP from 0 to 7). All
802.1ag
106

Advertisement

Table of Contents
loading

Table of Contents