Martin Audio CDD-LIVE! Series User Manual page 46

Table of Contents

Advertisement

 
 
 
CDD‐LIVE
The gain fader allows gain adjustment from ‐40 to +15dB. Precise values can be entered by typing directly in the box below the 
fader or values can be scrolled up or down using the up/down buttons. The increments that the up/down buttons will step is 
determined in the Preferences section, by default it will be 0.25dB. 
The mute button will mute the cabinet irrespective of the position of the gain fader and will turn red when active. 
There is comprehensive metering available. The bargraph to the left of the fader shows input level up to the maximum before 
input clip of +18dBu. The smaller meters to the right show the amplifier output levels for both the low frequency amplifier driving 
the LF driver and the high frequency amplifier driving the compression driver and show level prior to limit. If the levels reach the 
yellow segment you have reached the limiter threshold. A red segment indicated 3dB of gain reduction in the limiter. 
There is also a temperature read out showing the temperature of the DSP and amplifier module;‐ 
There is delay available which is very useful for time aligning CDD‐Live when used as an extra fill with a larger main system. The 
maximum delay available is 1 second. Values can either be typed directly into the Delay field or scrolled up and down using the 
arrow buttons. These increase or decrease the delay in increments of 10µs. 
The Input allows the connection mode to be changed from the default which is Auto to Analogue or Dante. This can either be 
done individually for each CDD or CSX Live or globally using the Input switch at the bottom of the overview Window. A global 
change will bring up the flowing window;‐ 
 
CDD‐LIVE User Guide V1.0 
 
 
 
 