Configuring the Unit Using the Internal Switches

Use internal Switchpacks S1 and S2 to manually configure the unit. Use the illustration
on page 24 to locate Switchpacks S1 and S2.
!
HANDLING PRECAUTIONS FOR STATIC-SENSITIVE DEVICES
This product is designed to protect sensitive components from
damage due to electrostatic discharge (ESD) during normal
operation. When performing installation procedures,
however, take proper static control precautions to
prevent damage to equipment. If you are not sure
of the proper static control precautions, contact
your nearest sales or service representative.
"
Procedure
To configure the unit using internal Switchpacks S1 and S2:
1. Power off the unit. Remove the enclosure cover by pushing a flat-blade
screwdriver through the slots on both sides of the housing to free the four inner
latches.
2. Locate Switchpack S1 on the circuit board.
3. Set Switch 1 on Switchpack S1 to ON to enable Switchpacks 1 and 2.
4. After you enable the switchpacks, you must set the switches to your desired
configuration. Refer to Tables 12 through 19.
5. Replace and secure the cover.
6. Power on the board to reset and enable the new configuration.