Send Remote Data Channel Loopback - Paradyne Hotwire 7975 User Manual

Paradyne m/sdsl standalone termination unit user's guide
Hide thumbs Also See for Hotwire 7975:
Table of Contents

Advertisement

Testing

Send Remote Data Channel Loopback

"
5-10
The local termination unit can send an Up or Down sequence to request the start
or stop of a Data Channel Loopback (DCLB) on a remote unit.
Local
NTU/LTU
Port
Framer
Interface
Procedure
To send a Remote DCLB:
1. Position the cursor at the Up or Down selection next to Send Remote DCLB
on the SYNC Data Port Tests screen.
2. Press the spacebar to select the desired code (Up or Down).
3. Position the cursor at the Start command next to Send Remote DCLB on the
SYNC Data Port Tests screen.
4. Press Enter.
The Status field is changed to Sending. The Up or Down sequence
transmission stops automatically after 10 seconds. You cannot stop the
sequence manually.
The Send Remote DCLB test cannot be started when a Send and Monitor 511
test is active on the network interface.
December 1998
Remote
NTU/LTU
Framer
CAP
CAP
Port
EIA-530
All 1s
Interface
Port
98-15935
7975-A2-GB20-40

Advertisement

Table of Contents
loading

Table of Contents