Data Channel Loopback - Paradyne Hotwire 7975 User Manual

Paradyne m/sdsl standalone termination unit user's guide
Hide thumbs Also See for Hotwire 7975:
Table of Contents

Advertisement

Data Channel Loopback

"
7975-A2-GB20-40
Data Channel Loopback (DCLB) loops the data from the network interface back
to the network. This loopback is located as closely as possible to the user data
port (DTE) interface.
NTU/LTU
Network
CAP
Framer
Interface
Procedure
To run a Data Channel Loopback:
1. Position the cursor at the Start command next to Data Channel Loopback on
the SYNC Data Port Tests screen.
2. Press Enter.
The Start command is changed to Stop.
3. To manually stop the test, verify that the cursor is positioned at the Stop
command.
4. Press Enter.
Data Channel Loopback cannot be started when any of the following tests is
active: Send and Monitor 511, Line Loopback, or Repeater Loopback on the
network interface, or a Data Terminal Loopback on the data port.
December 1998
Port
EIA-530
All 1s
Interface
Port
98-15934
Testing
5-9