Communication Protocol Options - Paradyne Hotwire 7975 User Manual

Paradyne m/sdsl standalone termination unit user's guide
Hide thumbs Also See for Hotwire 7975:
Table of Contents

Advertisement

Configuration Option Tables

Communication Protocol Options

A-12
Table A-5. Telnet Sessions Options (2 of 2)
Session Access Level
Possible Settings: Administrator, Operator
Default Setting: Administrator
The Telnet session access level is interrelated with the access level of the Login ID.
Refer to
ATI Access Levels
Administrator – This is the higher access level, permitting full control of the 7975
Termination Unit. Access level is determined by the Login ID. If Telnet Login Required is
disabled, the session access level is Administrator.
Operator – This is the lower access level, permitting read-only access to status and
configuration screens.
Inactivity Timeout
Possible Settings: Enable, Disable
Default Setting: Disable
Provides automatic logoff of a Telnet session.
Enable – The Telnet session terminates automatically after the Disconnect Time.
Disable – A Telnet session will not be closed due to inactivity.
Disconnect Time (Minutes)
Possible Settings: 1 – 60
Default Setting: 5
Number of minutes of inactivity before a Telnet session terminates automatically. Time
out is based on no keyboard activity.
H
Disconnect Time (minutes) option appears when Inactivity Timeout is enabled.
1 to 60 – The Telnet session is closed after the selected number of minutes.
To access the Communication Protocol Options screen, follow this menu
selection sequence:
Main Menu
Configuration
Management and Communication
Table A-6. Communication Protocol Options (1 of 2)
Node IP Address
Possible Settings: 000.000.000.000 – 223.255.255.255
Default Setting: 000.000.000.000
Specifies the Node IP address. This option is only available when the standalone unit is
configured as an LTU.
000.000.000.000 – 223.255.255.255 – Enter an IP address for the node. The range for
the first byte is 000 to 223, with the exception of 127. The range for the remaining three
bytes is 000 to 255.
December 1998
in Chapter 7, Security for more information.
Load Configuration From
Comm Protocol Options
7975-A2-GB20-40