H Viewing 7975 Standalone Termination Unit Leds - Paradyne Hotwire 7975 User Manual

Paradyne m/sdsl standalone termination unit user's guide
Hide thumbs Also See for Hotwire 7975:
Table of Contents

Advertisement

Viewing 7975 Standalone Termination Unit LEDs
Î
Î
7975-A2-GB20-40
This Field . . .
Contains . . .
Current Interval
The number of seconds which have elapsed in the current
Timer
15-minute interval. Maximum value is 900 seconds (15 minutes).
This counter resets every 15 minutes.
DSL Line Rate
The rate of the DSL line.
Current Interval
Performance data for the current 15 minutes.
Interval xx
Historical performance data for up to 96 15-minute intervals
(24 hours) where the value of xx is from 01 to 96.
The 7975 Standalone Termination Unit LEDs can be viewed on the Display LEDs
Status screen. This ATI status screen is available locally and remotely.
The 3 groups of LEDs are:
H
General LEDs display the status of the unit
H
Sync Port LEDs provide the status of the DTE interface
H
DSL Loop LEDs display the activity on the DSL network
To view the LED status screen, follow this menu selection sequence:
Main Menu
Status
main/status/leds
GENERAL
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
ALRM:Off
TEST Off
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
The LED status display screen is updated every 5 seconds. For information about
the meaning of 7975 Standalone Termination Unit LEDs, see 7975 Standalone
Termination Unit LEDs on page 4-10.
December 1998
Display LEDs
DISPLAY LEDs
SYNC PORT
P1:No DTR/RTS
ESC for previous menu
Monitoring the Unit
Hotwire
Model: 7975
DSL LOOP
P1:Lnk Up
Î Î
Î Î
MainMenu
Exit
4-9

Advertisement