Remote Digital Loopback - Paradyne 3800 User Manual

Comsphere 3800 series
Hide thumbs Also See for 3800:
Table of Contents

Advertisement

COMSPHERE 3800 Series Modems
Rem Digital Loop
Rem Digital Loop performs a remote digital loopback
(ITU-T V.54 Loop 2), Figure 8-2. This test can verify the
integrity of the local modem, the communications link,
and the remote modem. Any data or pattern entered at the
local DTE is sent to and returned from the remote modem.
For this test to operate properly, the modems must be
online and in Synchronous or Asynchronous Direct mode.
To access Rem Digital Loop from the Test branch,
make the following selections:
Test :
Rem_Digital_Loop
F1
F2
Press the
key until Rem_Digital_Loop appears.
Press any function key to start this test.
8-4
F3
Figure 8-2. Remote Digital Loopback
September 1998
Test : Remote Loop
Started
F1
F2
The message Started appears on the LCD, and the Test
LED (Model 3810 and Model 3811) lights for the duration
of the test.
If the Test Timeout configuration option is enabled,
Test Timeout appears at the conclusion of the test. If it is
disabled, the test operates until aborted. For more
information on the Test Timeout configuration option,
refer to the Tests section in Chapter 9.
To exit this function and remain in the Test branch,
press the
key. To exit and return to the Top-Level
menu, press the
key.
AT Command Equivalent
The AT command for Remote Loopback is &T6.