Paradyne COMSPHERE 3911 Installation And Operation Manual page 212

Comsphere 3900 series point-to-point/multipoint
Hide thumbs Also See for COMSPHERE 3911:
Table of Contents

Advertisement

COMSPHERE 3900 Series Modems
S-Register
S66
NMS Call Messages. Register determines if the modem sends
information regarding status (Call Progress) and/or sends summarized
call statistics (Call Connect) to the 6700 Series Network Management
System (NMS).
Register has the following values:
0 = Call Connect & Progress
1 = Disable
2 = Call Connect Only
3 = Call Progress Only
The factory setting is Call Connect & Progress.
S67
Directory Location 1 Callback. Register determines if the modem uses
the single number callback function.
Register has the following values:
0 = Disable
1 = Enable
The factory setting is Disable.
S69
Make Busy Via DTR. Register determines if the modem goes off-hook
(busy) when DTR is OFF.
Register has the following values:
0 = Disable
1 = Enable
The factory setting is Disable.
S70
V.27bis Train. Register controls the train time for V.27bis operation.
Register has the following values:
0 = Short
1 = Long
The factory setting is Short.
S71
XTXC Clamps TXC. Register allows the modem's TXC output to be
clamped off when TX Clock Source is configured for External.
Register has the following values:
0 = Enable
1 = Disable
The factory setting is Enable.
14-22
Table 14-3
(8 of 13)
391x Series S-Registers
Description
September 1998
DCP LCD
Command
Sequence
Configure\Edit\
Misc
Configure\Edit\
Misc
Configure\Edit\
Line Dialer
Configure\Edit\
Leased Line
Configure\Edit\
DTE Interface
3910-A2-GN32-40

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3910

Table of Contents