Diagnostic Control Panel Access
Use the DCP security access function to "lock" the DCP of any 391x Series modem and prevent
unwanted user access. Two options are available for this function: Grant and Deny.
Grant allows any branch of the Top-Level menu to be accessed from the DCP. Deny only allows
access to the Status branch of the Top-Level menu. All 391x Series modems are shipped from
the factory with DCP access granted.
To access the Front Panel (DCP) Security Access function, perform the following:
Press the
Press the
Press the
Select Grant to allow access or select Deny to lock DCP access.
Either selection results in a return to the Top-Level menu.
3910-A2-GN32-40
If a connection is established but the wrong password is stored, the status message
Password Invalid appears on the LCD. This configuration option must be enabled by the
remote user. (Refer to the Remote Access Password configuration option in Table 5-8 of
Chapter 5, DCP Configuration.)
The Remote mode command displays Other Test Active if an Analog Loopback test is
currently running.
This page of the manual is self supporting and can be removed to
prevent unwanted knowledge of the DCP security access
selections.
key three times.
key twice.
key once.
Frnt Panl Acces
Grant
F1
F2
September 1998
NOTE
Deny
F3
Remote Branch
13-5