Viewing And Modifying Server Configuration Information - NEC express5800 A2010b User Manual

Hide thumbs Also See for express5800 A2010b:
Table of Contents

Advertisement

Chapter 3 Setup
8.15

Viewing and Modifying Server Configuration Information

If you modify the properties shown below in /admin1/system1 target of SMASH-CLP, you can change operating
mode of the server.
Use show command to view, and set command to modify the property.
oemnec_PowerRedundancy
Use this property to specify redundancy mode of power supply unit (PSU). Available options are: -N
redundancy, N+1 redundancy, and non-redundancy.
oemnec_SASBatteryBackupUnit
Use this property to confirm if SAS card is installed or not, if SAS card is equipped with battery backup unit
(BBU). Setting can be changed by the set command.
If BBU is mounted on SAS card, changing this item to "installed" can reduce power consumption of the
server.
oemnec_PeriodicDiagnostis
Use this property to specify whether the automatic diagnosis is performed on CPU,memory, and PCIe card
regularly. Setting can be changed by the set command. When set to [Enabled], diagnosis is performed
automatically, and the test result is stored in Activity Log. You can view Activity Log by selecting
[Maintenance] tab → [Hardware Log] → [View ActivityLog] on remote management console.
oemnec_SpareClock
Use this property to specify which clock module (ClocK#1 or Clock#2) is to be assigned as a spare clock.
oemnec_SpareMemoryConfigurationMode
Use this property to specify connecting method for spare MR (memory module) that is not connected with
the running OS. Setting can be changed by the set command. You can select "Dynamic" (connect while OS
is running) or "Static" (connect while OS is not running).
oemnec_SparePciConfigurationMode
Use this property to specify connecting method for PCIe card that is not built in the running OS. Available
options are: Dynamic (connect PCIe card while the OS is running) or Static (connect PCIe card while the OS
is not running).
oemnec_FailingUnitRemoval
Use this property to specify whether the server is rebooted after disconnecting the failed component. When
set to "enabled", the failed component is disconnected and the server is rebooted. When set to "disabled",
the failed component is not disconnected and the operation is continued.
oemnec_Degraded Server Boot
Use this property to specify the server is rebooted automatically when partition is degraded due to
occurrence of failure. When "Boot" is specified, the server containing the degraded component is rebooted.
When "Notboot" is specified, the server containing the degraded component is not rebooted.
oemnec_Frb2Monitoring
Use this property to specify whether the monitoring timeout of FRB stall is enabled or disabled.
oemnec_PostMonitoring
Use this property to specify whether the monitoring timeout of POST stall is enabled or disabled.
oemnec_BootMonitoring
Use this property to specify whether the monitoring timeout of Boot stall is enabled or disabled and its
monitoring duration.
438
Express5800/A1040b, A2040b, A2020b, A2010b User's Guide