NEC express5800 A2010b User Manual page 309

Hide thumbs Also See for express5800 A2010b:
Table of Contents

Advertisement

Chapter 3 Setup
(1)
Change one time boot device
If you need to change boot device, select other than "No change". This setting is made valid when you execute
power ON next time, reset, cycle power, or OS shutdown reboot on the Web browser, not by the power button
on the server nor the virtual power button.
Setting
No change
Preboot eXecution Environment(PXE)
Hard Drive
FD/Primary removable media
CD/DVD Drive
Remote media (FD)
Remote media (CD/DVD)
Remote media (USB Memory)
Tips
(2)
System BIOS
Press this button to change settings of BIOS at next bootup. This setting is made valid when you execute power
ON, reset, cycle power, or OS shutdown reboot next time.
To perform [BIOS Recovery], you need the dedicated CD-ROM media separately. For details refer to Chapter 2
(1. System BIOS) in Maintenance Guide.
Setup item
Reset Param BIOS
BIOS PASSWORD Clear
BIOS Recovery
(3)
Power Control
Administrator or Operator privilege is required to use this feature.
Button
Power ON
Forces Power OFF
Power Cycle
System Reset
Boot according to setting of System BIOS.
Perform PXE boot.
Boot from hard disk drive connected with the managed server.
Boot from FD drive or removable media connected with the
managed server.
Boot from CD/DVD drive connected with the managed server.
Boot from FD drive (media) connected via remote media feature.
Boot from CD/DVD drive (media) connected via remote media
feature.
Boot from USB memory connected via remote media feature.
This operation is not currently supported.
Enable/Disable
When enabled, reset BIOS parameter setting.
Enable/Disable
When enabled, reset BIOS password.
Enable/Disable
When enabled, recover BIOS settings.
BIOS Recovery is a function which is for recovering BIOS update
using CD/DVD with SATA DVD drive when BIOS update has
failed.
Note: BIOS Recovery is dedicated for maintenance personnel,
not for users. Ask your service representative who is authorized
by NEC to use it.
Power on the managed server. If the server is already powered on, this button has
no effect.
Forcibly power off the managed server. If the server is already powered off, this
button has no effect.
Data may be lost by this operation.
Forcibly power off the managed server, and then on. If the server is already
powered off, this button has no effect.
Data may be lost by this operation.
Reset the managed server. If the server is already powered off, this button has no
effect.
Express5800/A1040b, A2040b, A2020b, A2010b User's Guide
7. Using Remote Management
Boot device
Current setting
When pressed
309

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800 a1040bExpress5800 a2020bExpress5800 a2040b

Table of Contents