Option List

4. Option List

4.1

Option List of Controllers

Operation Control System Optional Accessories
Type
FXFQ-P FXZQ-M FXCQ-M FXKQ-MA FXDQ-NB
No.
Item
Wireless
BRC7F634F
Remote
1
controller
Wired
2
Wired remote controller
with weekly schedule timer
Simplified remote
3
controller
Remote controller for
4
hotel use
★KRP1C63 ★KRP1B57
5
Adaptor for wiring
Wiring adaptor for
★KRP2A62
6-1
electrical appendices (1)
Wiring adaptor for
★KRP4AA53
6-2
electrical appendices (2)
7
Remote sensor
KRCS01-4B
Installation box for
Note 2, 3
8
adaptor PCB
KRP1H98
Centralized remote
9
DCS302CA61
controller
El. compo. box with earth
9-1
terminal (3 blocks)
10
Unified on/off controller
El. compo. box with earth
10-1
terminal (2 blocks)
Noise filter (for electromagnetic
10-2
interface use only)
11
Schedule timer
External control adaptor for outdoor
12
unit (Must be installed on indoor units)
DTA104A62
Interface adaptor for
13
SkyAir-series
Note:
1. Installation box (No.8) is necessary for each adaptor marked
2. Up to 2 adaptors can be fixed for each installation box.
3. Only one installation box can be installed for each indoor unit.
4. Up to 2 installation boxes can be installed for each indoor unit.
5. Installation box (No. 8) is necessary for second adaptor.
6. Installation box (No. 8) is necessary for each adaptor.
7. This adaptor is required when connecting with optional controller for centralized control.
8. BRC2A51 is also available.
Various PCBs
No.
Part name
1
Adaptor for wiring
2
DIII-NET Expander Adaptor
System Configuration
No.
Part name
1
Central remote controller
El. compo. box with earth terminal
1-1
(3 blocks)
2
Unified ON/OFF controller
El. compo. box with earth terminal
2-1
(2 blocks)
Noise filter (for electromagnetic
2-2
interface use only)
3
Schedule timer
R-407C/R-22
Interface adaptor
4
for SkyAir-series
R-410A
Central control
For UAT(Y)-
5
adaptor kit
K(A),FD-K
6
Wiring adaptor for other air-conditioner
DIII-NET
7
Expander Adaptor
7-1
Mounting plate
Note:
1. Installation box for
401
FXDQ-PB
BRC7E530
BRC7C62
BRC4C61
BRC4C65
Note 8
BRC2C51
★KRP1B61
★KRP1B56
KRP1B61
★KRP2A526
★KRP2A61
★KRP2A53
KRP2A61
★KRP4A536
★KRP4A51
★KRP4A54
KRP4A51
KRCS01-1
KRCS01-1
Note 4,6
Note 2, 3
Note 4, 6
KRP1BA101
KRP1B96
KRP1B101
★DTA104A52
DCS302CA61
DTA104A52
DTA104A61
DTA104A61
Model No.
KRP1B56
KRP1B57
PCB when equipped with auxiliary electric heater in the indoor unit.
KRP1B61
KRP1B3
Up to 1,024 units can be centrally controlled in 64 different groups.
DTA109A51
Wiring restrictions (max. length: 1,000 m, total wiring length: 2,000 m, max. number of
branches: 16) apply to each adaptor.
Model No.
DCS302C51
DCS302CA51
• Up to 64 groups of indoor units (128 units) can be connected, and ON/OFF, temperature
(FXFQ-P)
setting and monitoring can be accomplished individually or simultaneously. Connectable up
to 2 controllers in one system.
KJB311A
DCS301B51
DCS301BA51
(FXFQ-P)
• Up to 16 groups of indoor units (128 units) can be turned, ON/OFF individually or
simultaneously, and operation and malfunction can be displayed. Can be used in
KJB212A
combination with up to 8 controllers.
KEK26-1
DST301B51
• Programmed time weekly schedule can be controlled by unified control for up to 64 groups
DST301BA51
of indoor units (128 units). Can turn units ON/OFF twice per day.
(FXFQ-P)
★ DTA102A52
• Adaptors required to connect products other than those of the VRV System to the high-
★ DTA112B51
speed DIII-NET communication system adopted for the VRV System.
★ DTA107A55
* To use any of the above optional controllers, an appropriate adaptor must be installed on
the product unit to be controlled.
★ DTA103A51
• Up to 1024 units can be centrally controlled in 64 different groups.
• Wiring restrictions (max. length : 1,000m, total wiring length : 2,000m, max. number of
DTA109A51
branches : 16)
apply to each adaptor.
KRP4A92
• Fixing plate for DTA109A51
adaptor must be procured onsite.
FXDQ-M FXUQ-MA FXSQ-P FXMQ-MA FXMQ-P FXHQ-MA FXAQ-MA FXLQ-MA
BRC4C62
BRC7C528W
BRC4C62
BRC1E51
BRC1D61
BRC2C51
BRC3A61
KRP1B61
KRP1B61
★KRP2A62
KRP2A51
KRP2A61
★KRP4A53
KRP4A51
KRP4A51
KRCS01-1
Note 5
KRP1B97
KRP4A91
DTA104A61
KJB311AA
DCS301BA61
KJB212AA
KEK26-1A
DST301BA61
DTA104A61
DTA104A53
Note 7
DTA102A52
Function
Function
SiBE31-801_C
BRC4C65
BRC7E63W
BRC7E618
Note 8
BRC2C51
BRC3A61
★ KRP1C64
KRP1C3
★KRP2A61
★KRP2A62
★KRP2A61 KRP2A61
★KRP4AA51
★KRP4A52
★KRP4A51 KRP4A51
KRCS01-4B
KRCS01-1
Note 2, 3
Note 3
Note 2, 3
KRP4A96
KRP1C93
KRP4A93
DCS302CA61
DTA104A61
DTA104A62
DTA104A61
.
FXNQ-MA
BRC4C62
Note 8
BRC2C51
BRC3A61
KRP1B61
DTA104A61
Appendix