Connection Of The Load Voltage Reference Potential - Siemens S7-300 Installation Manual

Automation system
Hide thumbs Also See for S7-300:
Table of Contents

Advertisement

&RQQHFWLQJ WKH UHIHUHQFH SRWHQWLDO RI WKH ORDG YROWDJH
Numerous output modules require an additional load voltage for switching control
devices.
The table below shows how to connect the load voltage reference potential M
for the various configuration versions.
Table 5-9
,QVWDOODWLRQ
grounded
ungrounded Connect M
S7-300 Automation System, Hardware and Installation: CPU 312IFM - 318-2 DP
A5E00203919-01

Connection of the load voltage reference potential

1RQLVRODWHG PRGXOHV
Connect M
with M
external
on the CPU
with M
external
on the CPU
,VRODWHG PRGXOHV
Connect or do not connect
M
to the common
external
grounding line
Connect or do not connect
M
to the common
external
grounding line
&RQILJXULQJ
external
5HPDUNV
-
ungrounded operation
of CPU 312 IFM is not
possible
5-27