File Format - Omron fq2 User Manual

Hide thumbs Also See for fq2:
Table of Contents

Advertisement

File Format

Image data: Image data is saved in a special format for OMRON Vision Sensors. (The file name extension is
IFZ.)
Measurement data: Measurement data is saved in the following CSV format.
1)
2)
Item
*1
1)
Date
*1
2)
Time
3)
Measurement ID
4)
Scene No.
5)
Judge
6)
Inspection item
region
7)
Expression region
*1:
The data and time are not recorded with the measurement data. Therefore, this is not the date that the measurement was executed. This
is the date that the PC Tool or the Touch Finder obtained the data from the Sensor.
Changing the Format for Saving Measurement Data
The output CSV file format can be changed according to the external device.
(Setup Mode or Run Mode) − [TF settings] − [File format] − [Logging data file]
1
Press [Output format].
2
Change the required items in the CSV format.
3
Press [Back].
Item
Symbol
Field separator
None, comma (default), tabs, space, colon, semicolon, CR, or CR+LF
Decimal symbol
None, point (default), or comma
Record separator
None, comma, tabs, space, colon, semicolon, CR, or CR+LF (default)
Enabling File Logging
You must enable file logging before you can execute it.
(Setup Mode) − [TF settings] − [Logging setting]
1
Press [ON].
212
Logging Measurement Data and Image Data
3)
4)
5)
Format
YYYY/MM/DD
hh:mm:ss
---
---
---
I(inspection_item_number).(measure
ment_item)(detection_point)
Example: The correlation of the sec-
ond detection point in a search for
inspection item number 0 would be
given as follows: I0.CR2
Z0.D**
Example: The fourth registered
expression would be given as fol-
lows: Z0.D04
6)
Description
This is the date that the measurement data was obtained from
the Sensor.
This is the time that the measurement data was obtained from
the Sensor.
This is the measurement ID information.
Scene number
Overall judgement
0: OK, −1: NG, −2: NC (not measured)
The data selected for logging in the [Measurement data] under
[Log setting] is output. If multiple results are detected, only the
maximum number of data items that is set in the [Measurement
data] are output.
This is the expression results for each expression.
7)