Omron fq2 User Manual page 342

Hide thumbs Also See for fq2:
Table of Contents

Advertisement

● Clear Measurement Values (Command Code: 2010 0010)
Command (PLC to Vision Sensor)
First word of
command
12 to 15
area
+2
+3
Response (Vision Sensor to PLC)
First word of
response area
12 to 15
+2
+3
+4
+5
● Save Data in Sensor (Command Code: 3010 0010)
Command (PLC to Vision Sensor)
First word of
command
12 to 15
area
+2
+3
Response (Vision Sensor to PLC)
First word of
response area
12 to 15
+2
+3
+4
+5
● Re-register Model (Command Code: 4010 0010)
Command (PLC to Vision Sensor)
First word of
command
12 to 15
area
+2
+3
340
PLC Link Connections
Bits
8 to 11
0010
0000
0000
0000
Bits
8 to 11
0010
0000
0000
0000
0000
0000
0000
0000
Bits
8 to 11
0011
0000
0000
0000
Bits
8 to 11
0011
0000
0000
0000
0000
0000
0000
0000
Bits
8 to 11
0100
0000
0000
0000
4 to 7
0 to 3
0001
0000
0001
0000
4 to 7
0 to 3
0001
0000
0001
0000
0000
0000
0000
0000
4 to 7
0 to 3
0001
0000
0001
0000
4 to 7
0 to 3
0001
0000
0001
0000
0000
0000
0000
0000
4 to 7
0 to 3
0001
0000
0001
0000
Contents
Command code
Contents
Command code
The command code for which the
response applies is stored.
Response code
Command execution result
0: OK, FFFFFFFF: NG
Contents
Command code
Contents
Command code
The command code for which the
response applies is stored.
Response code
Command execution result
0: OK, FFFFFFFF: NG
Contents
Command code
FQ2 User's Manual