Setting the Output Format
[In/Out] − [I/O setting] − [Output data setting] − [Noprotocol data output]
1
Press [Output format].
2
Set [Output form] to [ASCII] or [Binary].
3
Set the data format for the data form that you select-
ed.
Item
For ASCII
Digits of
integer
Digits of
decimal
Negative
0 Sup-
pressed
Field sepa-
rator
Record
separator
For Binary
Decimal
output form
FQ2 User's Manual
Controlling Operation and Outputting Data with TCP No-protocol Communications
Description
Sets the number of digits in the integer part
of the number.
Set the number of digits in the integer part. 0 to 4 digits
Sets the way to express negative numbers. − or 8
Sets whether to use zero suppression.
Sets the field separator.
Sets the record separator.
Set the decimal output form for numerical
data.
ASCII
Binary
Setting range
1 to 10 digits
Default: 6 digits
Default: 4 digits
Default: −
Yes or No
Default: No
OFF, comma, tab, space, CR, LF,
or CR+LF
Default: OFF
OFF, comma, tab, space, CR, LF,
or CR+LF
Default: OFF
Floating point or fixed point
(default: Fixed point)