Omron fq2 User Manual page 134

Hide thumbs Also See for fq2:
Table of Contents

Advertisement

Step 2
Teaching
Teaching means to store the region as reference data for the measurement.
− [Inspection]
[Inspect]
1
Press [Teach].
2
Place the object that is to be used as the measure-
ment reference in front of the camera.
3
Move the rectangle to the location to be measured.
4
Press [OK].
Changing the Measurement Region: p. 102
Step 3
Adjusting the Judgement Parameters
− [Inspection]
[Inspect]
1
Press [Judgement].
2
Press the parameters and set the range that is to be
judged as OK.
Continuous measurements will be performed for the im-
ages that are displayed. The measured value is dis-
played beside the parameter name.
Note
You can change the parameters for judgement conditions on the
Display Settings Display. Press
of the display to switch to the Display Settings Display.
3
Press [OK] to enter the value.
132
Inspecting with the Edge Pitch Inspection Item
− [Add item.] − [Edge Pitch] − [Settings] Tab Page
− [Add item.] − [Edge Pitch] − [Settings] Tab Page
− [Display setting] on the right
[
]
The middle arrow is the direction
for detecting an edge.
Moves the end point of
Moves the starting
the measurement region.
point of the
measurement region.
Drag to move
Changes the width
the region.
of the measure-
ment region.
Upper limit
Lower limit
Blue for OK. Red for NG.
FQ2 User's Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents