Omron fq2 User Manual page 344

Hide thumbs Also See for fq2:
Table of Contents

Advertisement

● Get Scene Number (Command Code: 1000 0020)
Command (PLC to Vision Sensor)
First word of
command
12 to 15
area
+2
+3
Response (Vision Sensor to PLC)
First word of
response area
12 to 15
+2
+3
+4
+5
+6
+7
● Select Scene (Command Code: 1000 0030)
Command (PLC to Vision Sensor)
First word of
command
12 to 15
area
+2
+3
+4
+5
Response (Vision Sensor to PLC)
First word of
response area
12 to 15
+2
+3
+4
+5
342
PLC Link Connections
Bits
8 to 11
0001
0000
0000
0000
Bits
8 to 11
0001
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Bits
8 to 11
0001
0000
0000
0000
0000
0000
0000
0000
Bits
8 to 11
0001
0000
0000
0000
0000
0000
0000
0000
4 to 7
0 to 3
0000
0000
0010
0000
4 to 7
0 to 3
0000
0000
0010
0000
0000
0000
0000
0000
0000
0000
0000
0000
4 to 7
0 to 3
0000
0000
0011
0000
0000
0000
0000
0000
4 to 7
0 to 3
0000
0000
0011
0000
0000
0000
0000
0000
Contents
Command code
Contents
Command code
The command code for which the
response applies is stored.
Response code
Command execution result
0: OK, FFFFFFFF: NG
Response data
Acquired scene number
Contents
Command code
Scene number
Contents
Command code
The command code for which the
response applies is stored.
Response code
Command execution result
0: OK, FFFFFFFF: NG
FQ2 User's Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents