Table 42
Cable attenuation at 256 kHz and 21.1 degrees C (70 degrees F)
Cable
type
26 AWG
dB/kft
PIC
4.2
Pulp
4.3
6
Reject loops whose expected pulse loss is greater than 12 dB.
Example of applying Procedure 53
Section 1:
Mainframe bulkhead to DF1 - 500m, 26 AWG PIC, underground
Section 2:
DF1 to DF2 - 200m, 26 AWG PIC, inside
Section 3:
DF2 to terminal - 24 AWG NT D-inside
Therefore:
SL1 = 1.5 km, SL2 = 0.2 km, SL3 = 0.1 km
From Table 42 on
L1 = 13.7 dB/km, L2 = 13.7 dB/km, L3 = 13.3 dB/km.
Using the equation in Step 2, we arrive at the following:
CSL1 = 6.85 dB, CSL2 = 2.74 dB, and CSL3 = 1.33 dB
Temperature corrections:
Using correction factors of TCF1 = 1.04, and TCF2 and TCF3 = 1,
and using the equation in Step 3 results in TCL1 = 7.12 dB,
TLC2 = 2.74 dB, and TCL3 = 1.33 dB.
Expected pulse loss (EPL) value:
Neglecting any junction loss (see the note in Step 4), Step 5
results in an EPL value of TSL1 + TSL2 + TSL3 + 0 = 11.19 dB.
This is under the 12 dB limit and meets the criteria.
24 AWG
dB/km
dB/kft
13.7
3.1
14.3
3.5
Telephones and Consoles
Digital telephones line engineering
page 305
and Table 43 on
22 AWG
dB/km
dB/kft
10.2
2.5
11.4
2.7
Description, Installation, and Operation
Page 305 of 504
page
306:
19 AWG
dB/km
dB/kft
8.1
1.7
9.0
2.0
dB/km
5.6
6.6