Furuno FCV-1900/B/G Installation Manual page 29

Table of Contents

Advertisement

Output
Frequency
power (kW)
(kHz)
3
Output
Frequency (kHz)
power (kW)
1
42-65/130-210
42-65/85-135
42-65/150-250
2
38-75/130-210
38-75/80-130
3
28-60/130/210
28-60/80-130
Manual setting
For transducer not listed in the table above, set [HF XDCR Select] to [Manual], then
set the TX power, frequency and bandwidth.
1. Display the [XDCR setting menu], referring to the preceding procedure.
2. Set [HF XDCR Select] to [Manual].
Confirm that the high freq. transducer is connected to the HF port.
3. Set [HF connection] to [Connected].
4. Set [Voltage] according to the transducer voltage.
5. Set a frequency from the [Freq.] menu.
The band width is automatically set, however it can be entered manually with
[Band width].
6. Set the LF transducer similarly.
Single frequency setting
When using only one transducer, connect the transducer to either the high or low
transducer port, then set the connected port [connection] to [Connected].
Model
28
28BL-12HR
38
38BL-15HR
50
50BL-24HR
68
68F-30H
88
88F-126H
107
100B-10R
150
150B-12H
200
200B-12H
Dual frequency transducers
Model
CM265LH
CM265LM
CM275LH-W
PM111LH
PM111LM
CM599LH
CM599LM
22
3. INITIAL SETTINGS
Remarks
Remarks
ACCU-FISH
compatible
Wide beam type
ACCU-FISH
compatible

Hide quick links: