2. WIRING
2.2.3
Transducer
Lay the transducer cable well away from power cables to prevent interference. Con-
nect the cable to the transducer port (for high frequency and/or low frequency) at the
connector on the processor unit. Fabricate the cables as shown below.
Note: If the transducer cable label interferes with installation, remove the label. Re-
cord the cable assembly series number then store it for reference.
Transducer cable connection
1. Unfasten three binding screws to remove the connector cover.
2. Disconnect the WAGO connector (CN-2) on the right side of the connector panel.
3. Connect the transducer cable to the WAGO connector referring to the intercon-
nection diagram at the back of this manual. For dual frequency connections, con-
nect both transducer cables to the WAGO connector.
The terminal opener is attached to the connector board on the cover.
Push
Terminal
opener
Wire
Twist
Sheath
Pull the cores out from shield
and remove cushioning materials.
Wrap the braided shield around the sheath.
Clamp here with the metal fixture.
Procedure
1. Twist core.
2. Insert terminal opener and push.
3. Insert wire into hole.
4. Release terminal opener.
5. Pull wire to confirm it is correctly inserted.
100
Braided shield
Vinyl tape
Connector cover
Binding screws (3 pcs.)
11
Terminal opener