Main Supply Hose - Low Pressure; Regulator - Jayco 2004 Talon ZX Owner's Manual

Table of Contents

Advertisement

I
WARNING: Keep the pigtail hose away from sharp edges of the cylinder collar, rigid
corners, walls, doors or other compartment structures including the cover.
Note: The regulator is typically installed with the inlet fittings at the same level as the
cylinder outlet valves. Due to bracket design, wing nut clearance or cover
restrictions, the regulator fittings may not be in perfect alignment with the cylinder
valves. A variance of two (2) inches (5 cm) above or below the line will permit the
hoses to be properly installed.

Main Supply Hose - Low Pressure

The main supply hose will be attached from regulator to brass manifold fitting in frame of coach.
Swivel brass nut on main hose will be your final attachment. Several things to remember each time
container is removed:
1. Check that ALL fittings are tight.
2. Check that ALL connections are tested with leak solution.
3. Open the main valve slowly to avoid a fast rush of gas to excess flow valve causing gas
freeze up. Should you experience a gas "freeze-up," close the main valve and wait 15
minutes before trying again.
4. Listen carefully - a "hissing" sound longer than one second may indicate a gas leak. Close the
valve and search for the leak.
ALL GAS LINES HAVE BEEN CHECKED WITH
AIR PRESSURE. DEALERS ARE REQUIRED TO
RECHECK AND ADJUST PRESSURE BEFORE
DELIVERY TO CUSTOMERS.

Regulator

The regulator is the heart of your LP gas system, with
internal moving parts. Its function is to reduce the high and
varied pressure from the LP container to safe and consistent
low operating pressure. The inlet is the first stage and
reduces container pressure to 10-13 pounds. The second
stage will reduce the 10-13 pound pressure to an operating
pressure of 11" W.C. (Water Column) or 6.35 oz. of outlet
pressure to the coach system. The second stage is adjustable
and will need to be adjusted for precise operation. We
suggest this normal maintenance procedure be performed
once per year. Have only an authorized and competent
technician make any adjustments.
The Systems
3/8" MPT x 1/2" Female
Flare Swivel
Fig. 4-18
47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Talon zx

Table of Contents